Temperature dependence of nickel ion release from nitinol medical devices
- 19 December 2020
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (8) , 1188-1197
Abstract
Nitinol exhibits unique (thermo)mechanical properties that make it central to the design of many medical devices. However, nitinol nominally contains 50 atomic percent nickel, which if released in sufficient quantities, can lead to adverse health effects. While nickel release from nitinol devices is typically characterized using in vitro immersion tests, these evaluations require lengthy time periods. We have explored elevated temperature as a potential method to expedite this testing. Nickel release was characterized in nitinol materials with surface oxide thickness ranging from 12 to 1564 nm at four different temperatures from 310 to 360 K. We found that for three of the materials with relatively thin oxide layers, ≤ 87 nm nickel release exhibited Arrhenius behavior over the entire temperature range with activation energies of 80 to 85 kJ/mol. Conversely, the fourth ''black–oxide'' material, with a much thicker, complex oxide layer, was not well characterized by an Arrhenius relationship. Power law release profiles were observed in all four materials; however, the exponent from the thin oxide materials was approximately 1/4 compared with 3/4 for the black–oxide material. To illustrate the potential benefit of using elevated temperature to abbreviate nickel release testing, we demonstrated that a > 50 day 310 K release profile could be accurately recovered by testing for less than 1 week at 340 K. However, because the materials explored in this study were limited, additional testing and mechanistic insight are needed to establish a protective temperature scaling that can be applied to all nitinol medical device components.Keywords
Funding Information
- U.S. Food and Drug Administration
- U.S. Department of Energy
- Oak Ridge Institute for Science and Education
This publication has 22 references indexed in Scilit:
- Biomedical Applications of Shape Memory AlloysJournal of Metallurgy, 2011
- Enhancement of nickel elution by lipopolysaccharide-induced inflammationJournal of Dermatological Science, 2011
- Metal release from stainless steel, Co–Cr–Mo–Ni–Fe and Ni–Ti alloys in vascular implantsCorrosion Science, 2008
- Fractional conservation of massAdvances in Water Resources, 2008
- The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridationJournal of Biomedical Materials Research Part A, 2007
- Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion releaseJournal of Biomedical Materials Research Part A, 2006
- Effect of chemical etching and aging in boiling water on the corrosion resistance of nitinol wires with black oxide resulting from manufacturing processJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Acute nickel toxicity in electroplating workers who accidently ingested a solution of nickel sulfate and nickel chlorideAmerican Journal of Industrial Medicine, 1988
- Tracer impurity diffusion in single-crystal rutile (TiO2−x)Journal of Physics and Chemistry of Solids, 1985