Magnetization transfer in magnetic resonance fingerprinting
- 25 November 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 128-141
Abstract
Purpose: To study the effects of magnetization transfer (MT, in which a semi‐solid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF).Methods: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off‐resonance MT pulses and a dictionary with an MT dimension, generated by incorporating a two‐pool model, were used to estimate the fractional pool size in addition to the , T1, and T2 values. The proposed method was evaluated in the human brain.Results: Simulations and phantom experiments showed that an MRF signal obtained from a cross‐linked bovine serum sample is influenced by MT. Using a dictionary based on an MT model, a better match between simulations and acquired MR signals can be obtained (NRMSE 1.3% vs. 4.7%). Adding off‐resonance MT pulses can improve the differentiation of MT from T1 and T2. In vivo results showed that MT affects the MRF signals from white matter (fractional pool‐size ~16%) and gray matter (fractional pool‐size ~10%). Furthermore, longer T1 (~1060 ms vs. ~860 ms) and T2 values (~47 ms vs. ~35 ms) can be observed in white matter if MT is accounted for.Conclusion: Our experiments demonstrated a potential influence of MT on the quantification of T1 and T2 with MRF. A model that encompasses MT effects can improve the accuracy of estimated relaxation parameters and allows quantification of the fractional pool size.Keywords
All Related Versions
Funding Information
- National Institutes of Health (NIH R21 EB020096, NIH R01 AR070297, NIH R01 EB026456)
This publication has 43 references indexed in Scilit:
- Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance FingerprintingJournal of Magnetic Resonance Imaging, 2018
- Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simpleJournal of Magnetic Resonance Imaging, 2014
- Transmit field inhomogeneity and T1estimation errors in breast DCE‐MRI at 3 teslaJournal of Magnetic Resonance Imaging, 2013
- Magnetization transfer ratio and myelin in postmortem multiple sclerosis brainAnnals of Neurology, 2004
- Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)‐algorithm: Principles and applications to hyperecho and TRAPS sequencesMagnetic Resonance in Medicine, 2003
- Determination of optimal angles for variable nutation proton magnetic spin‐lattice, T1, and spin‐spin, T2, relaxation times measurementMagnetic Resonance in Medicine, 2003
- Different magnetization transfer effects exhibited by the short and longT2 components in human brainMagnetic Resonance in Medicine, 2000
- A comparison between magnetization transfer ratios and myelin water percentages in normals and multiple sclerosis patientsMagnetic Resonance in Medicine, 1998
- Magnetization Transfer and T2 Relaxation Components in TissueMagnetic Resonance in Medicine, 1995
- In vivo visualization of myelin water in brain by magnetic resonanceMagnetic Resonance in Medicine, 1994