Reducing Load Transfer to Buried Pipes Through Coupled Use of Geogrid Reinforcement and Sand Rubber Zone in the Backfill Material
Open Access
- 27 August 2024
- journal article
- research article
- Published by Springer Nature in Transportation Infrastructure Geotechnology
- Vol. 11 (6) , 3878-3902
Abstract
A laboratory study, consisting of 21 tests, was conducted to examine precisely the impact of using a sand-rubber mixture with three different ratios of rubber (3, 5, and 7%) in a particular zone within the backfill and a geogrid reinforcement on the pressure transferred to buried pipes from surface loads. The pipe was buried at two different burial depths of 1.5 and 2 times the pipe diameter. Tests were conducted with a geogrid-reinforcement layer placed above and below the sand-rubber zone to determine the optimal performance of the proposed system. The findings from these tests are expected to contribute valuable insights into the development of effective strategies for reducing the impact on buried pipes and enhancing their overall resilience, particularly in the face of increasing surface loading. The results revealed that using a rubber ratio of 5% would present the optimum rubber ratio and using a geogrid layer above the sand-rubber zone would provide additional stability, where the bearing capacity of the system was increased by 33.7%, independent of the pipe burial depth and rubber ratio. Furthermore, the use of a sand-rubber mixture and a geogrid layer contributed to decreasing the pressure transferred to the pipe crown and the deformation of the soil surface, respectively.Keywords
This publication has 35 references indexed in Scilit:
- Numerical behaviour of buried flexible pipes in geogrid-reinforced soil under cyclic loadingComputers and Geotechnics, 2020
- Combined Use of Jute Geotextile-EPS Geofoam to Protect Flexible Buried Pipes: Experimental and Numerical StudiesInternational Journal of Geosynthetics and Ground Engineering, 2017
- Methods of protecting buried pipelines and culverts in transportation infrastructure using EPS geofoamGeotextiles and Geomembranes, 2015
- Bearing capacity of a square model footing on sand reinforced with shredded tire – An experimental investigationConstruction and Building Materials, 2012
- Combined use of geocell reinforcement and rubber–soil mixtures to improve performance of buried pipesGeotextiles and Geomembranes, 2012
- Interaction between geogrid reinforcement and tire chip–sand lightweight backfillGeotextiles and Geomembranes, 2010
- Analytical modeling of geogrid reinforced soil foundationGeotextiles and Geomembranes, 2009
- Laboratory tests of small-diameter HDPE pipes buried in reinforced sand under repeated-loadGeotextiles and Geomembranes, 2008
- Bearing capacity and settlement of tire-reinforced sandsGeotextiles and Geomembranes, 2004
- Bearing capacity tests on geogrid-reinforced clayGeotextiles and Geomembranes, 1992