Factors affecting corona on twin-point gaps under dc and ac HV
Author:
- I.A. MetwallyIMI.A. Metwally
- 1 January 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 3 (4) , 544-553
Abstract
The factors affecting corona formation on twin-point/plane gaps are investigated both theoretically and experimentally. In the theoretical analysis, an electrostatic field computation program based on the charge simulation method was used to get the electric field profile on the plate for different gap lengths and interspacings between the two points. Also, the effect of voltage level, air pressure and gap length on the number of axial streamers occurring across the critical field line was introduced for a constant time duration. The variation of the integral of the ionization coefficient with the axial length from the point was studied. Finally, a study of the effect of air pressure and gap length on both the corona inception voltage and critical length was presented. Corona formation in single and twin-point/plane gaps also was investigated experimentally under both high direct and alternating voltages. There are many factors affecting such corona formation. The investigated factors were the interspacing between the two points, gap length between the point and the plane, ambient temperature, relative humidity, polarity or frequency of the applied voltage, and electrode material. In order to study and explain such phenomena, a photographic investigation together with a simultaneous measurement of both the applied voltage and the corona current were introduced. Curve fitting of the dc corona current vs. gap length and voltage for both single and twin-point/plane gaps gave the conventional relationship, but in case of twin point the power of the gap length varies between 1.2 and 1.3.Keywords
This publication has 4 references indexed in Scilit:
- Current-density distribution on a plane cathode in DC glow and streamer corona regimes in airIEEE Transactions on Electrical Insulation, 1993
- Assessment and improvement of electric-field measurements using a bias probe with particular reference to twin-point-plane geometryIEE Proceedings A Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1987
- Observation of corona phenomena at very high direct voltagesIEE Proceedings A Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1986
- Systematic study of the electrical characteristics of the ``Trichel'' current pulses from negative needle-to-plane coronasJournal of Applied Physics, 1974