Corrosion resistance of Ti6Al4V alloy coated with caprolactone-based biodegradable polymeric coatings
Authors:
- W. KajzerWKW. Kajzer
- J. JaworskaJJJ. Jaworska
- K. JelonekKJK. Jelonek
- J. SzewczenkoJSJ. Szewczenko
- A. KajzerAKA. Kajzer
- K. NowińskaKNK. Nowińska
- A. HercogAHA. Hercog
- M. KaczmarekMKM. Kaczmarek
- J. KasperczykJ. Kasperczyk
- 31 March 2018
- journal article
- research article
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
- Vol. 20 (1) , 30-38
Abstract
The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.Keywords
This publication has 17 references indexed in Scilit:
- Polycaprolactone coating with varying thicknesses for controlled corrosion of magnesiumJournal of Coatings Technology and Research, 2013
- The Influence of Chain Microstructure of Biodegradable Copolyesters Obtained with Low-Toxic Zirconium Initiator toIn VitroBiocompatibilityBioMed Research International, 2013
- Engineering of bone fixation metal implants biointerface—Application of parylene C as versatile protective coatingMaterials Science and Engineering: C, 2012
- Parylene coatings on stainless steel 316L surface for medical applications — Mechanical and protective propertiesMaterials Science and Engineering: C, 2012
- Silane–parylene coating for improving corrosion resistance of stainless steel 316L implant materialCorrosion Science, 2011
- Degradation of copolymers obtained by ring-opening polymerization of glycolide and ɛ-caprolactone: A high resolution NMR and ESI-MS studyPolymer Degradation and Stability, 2008
- Comparative study of the hydrolytic degradation of glycolide/L‐lactide/ε‐caprolactone terpolymers initiated by zirconium(IV) acetylacetonate or stannous octoateJournal of Applied Polymer Science, 2007
- Shape Memory Behavior of Novel (l-Lactide−Glycolide−Trimethylene Carbonate) TerpolymersBiomacromolecules, 2007
- Structure−Property Relationships of Copolymers Obtained by Ring-Opening Polymerization of Glycolide and ε-Caprolactone. Part 1. Synthesis and CharacterizationBiomacromolecules, 2004
- Bioabsorbable implant material reviewOperative Techniques in Sports Medicine, 2004