A Rapid Torsion Method for Measuring the Viscosity of Silica Glasses up to 2200°C
Author:
- 1 March 1984
- journal article
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 67 (3) , 213-222
Abstract
A thin, heated glass rod fixed at one end is quickly rotated around its axis in a small vertically positioned tube furnace. A computer is used to determine the temperature‐viscosity correlation by solving an integral equation from the measurement of the torsion moment, the speed of rotation, the diameter of the rod, and the knowledge of the temperature profile inside the tube. The advantages of this new method are the small sample mass of about 0.5 g, the fast measurement procedure, the possibility of using high temperatures, and the fact that there is no contact of the sample with any solid materials. Also, lengthwise strips made of glass tubings can be used. Some examples of measuring the viscosities in the working range of 10 5 to 10 10 dPa. s of commercial silica glasses up to 2200°C are shown. Maximum deviations of ±14 K are possible.Keywords
This publication has 5 references indexed in Scilit:
- Experimental Evaluation of Beam‐Bending Method of Determining Glass Viscosities in the Range 10 8 to 10 15 PoisesJournal of the American Ceramic Society, 1963
- Viscosity of Molten SilicaJournal of Applied Physics, 1959
- Viscous flow in silica and binary liquid silicatesTransactions of the Faraday Society, 1955
- Viscosity measurements with glassProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1925
- XLI. On the viscosity of pitch-like substancesJournal of Computers in Education, 1904