Poly(dimethylsiloxane) cross-linked carbon paste electrodes for microfluidic electrochemical sensing
- 1 January 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (15) , 3177-3184
Abstract
Recently, the development of electrochemical biosensors as part of microfluidic devices has garnered a great deal of attention because of the small instrument size and portability afforded by the integration of electrochemistry in microfluidic systems. Electrode fabrication, however, has proven to be a major obstacle in the field. Here, an alternative method to create integrated, low cost, robust, patternable carbon paste electrodes (CPEs) for microfluidic devices is presented. The new CPEs are composed of graphite powder and a binder consisting of a mixture of poly(dimethylsiloxane) (PDMS) and mineral oil. The electrodes are made by filling channels molded in previously cross-linked PDMS using a method analogous to screen printing. The optimal binder composition was investigated to obtain electrodes that were physically robust and performed well electrochemically. After studying the basic electrochemistry, the PDMS-oil CPEs were modified with multi-walled carbon nanotubes (MWCNT) and cobalt phthalocyanine (CoPC) for the detection of catecholamines and thiols, respectively, to demonstrate the ease of electrode chemical modification. Significant improvement of analyte signal detection was observed from both types of modified CPEs. A nearly 2-fold improvement in the electrochemical signal for 100 μM dithiothreitol (DTT) was observed when using a CoPC modified electrode (4.0 ± 0.2 nA (n = 3) versus 2.5 ± 0.2 nA (n = 3)). The improvement in signal was even more pronounced when looking at catecholamines, namely dopamine, using MWCNT modified CPEs. In this case, an order of magnitude improvement in limit of detection was observed for dopamine when using the MWCNT modified CPEs (50 nM versus 500 nM). CoPC modified CPEs were successfully used to detect thiols in red blood cell lysate while MWCNT modified CPEs were used to monitor temporal changes in catecholamine release from PC12 cells following stimulation with potassium.Keywords
This publication has 49 references indexed in Scilit:
- Fabrication of magnetic porous pseudo-carbon paste electrode electrochemical biosensor and its application in detection of schistosoma egg antigenElectrochemistry Communications, 2010
- Electrochemistry at carbon nanotubes: perspective and issuesChemical Communications, 2009
- Analysis of sudan I, sudan II, sudan III, and sudan IV in food by HPLC with electrochemical detection: Comparison of glassy carbon electrode with carbon nanotube-ionic liquid gel modified electrodeFood Chemistry, 2008
- Electrochemical techniques for microfluidic applicationsElectrophoresis, 2008
- Electrochemical immunosensor and biochemical analysis for carcinoembryonic antigen in clinical diagnosisMicrochimica Acta, 2008
- Electrochemical detection of DNA hybridization based on polypyrrole/ss-DNA/multi-wall carbon nanotubes paste electrodeTalanta, 2007
- Carbon nanotube detectors for microchip CE: Comparative study of single‐wall and multiwall carbon nanotube, and graphite powder films on glassy carbon, gold, and platinum electrode surfacesElectrophoresis, 2007
- Simultaneous analysis of nitrate and nitrite in a microfluidic device with a Cu-complex-modified electrodeElectrophoresis, 2006
- Fast and simultaneous detection of prominent natural antioxidants using analytical microsystems for capillary electrophoresis with a glassy carbon electrode: A new gateway to food environmentsElectrophoresis, 2005
- Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual‐Electrode Amperometric DetectionElectroanalysis, 2005