Optimization of sample preparation and a quadrupole ICP-MS measurement protocol for the determination of elemental impurities in pharmaceutical substances in compliance with USP guidelines
- 3 August 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 27 (11) , 1909-1919
Abstract
Both new guidelines concerning elemental impurity limit concentrations and novel analytical procedures for elemental analysis of pharmaceutical substances are being adopted by the United States Pharmacopeia (USP). This paper outlines the optimization of two sample preparation procedures for organic pharmaceutical excipient products, one relying on direct dissolution in an aqueous medium and another on microwave-assisted acid digestion. Optimization particularly involved the stabilization and reliable determination of Hg, Pd and Os. Analyte concentrations and spike recoveries were determined in two organic pharmaceutical excipients using a quadrupole ICP-MS instrument equipped with a collision–reaction cell. Aqueous dissolution was achieved with 0.009 mM KBrO3 in 1% (v/v) HNO3 and 1% (v/v) HCl and microwave-assisted acid digestion was performed with aqua regia. Polyatomic interferences originally hampering the accurate determination of 51V, 52Cr, 53Cr, 55Mn, 56Fe and 75As were eliminated through introduction of He/H2 collision–reaction gas at a flow rate of 4.5–5.1 ml min−1 and applying a kinetic energy barrier of 3 V between the hexapole collision–reaction cell and the quadrupole analyzer. Limits of detection were more than a factor of ten lower than the proposed limit concentrations for parenteral administration and the impurity concentrations in the products tested never exceeded the limit concentrations defined by USP. Elemental spike recoveries ranged between 93.8 and 109.9% when standard addition was used for calibration, with relative standard deviations (RSDs) ≤12.7%. It is expected that the proposed procedures can be directly implemented for routine impurity analysis of a broad spectrum of pharmaceutical substances.Keywords
This publication has 9 references indexed in Scilit:
- Accuracy improvement in the determination of palladium in pharmaceuticals by eliminating volatility error when using ICP-MS coupled with direct introduction of sample dissolved in organic solventsJournal of Analytical Atomic Spectrometry, 2011
- A rapid ICP-MS screen for heavy metals in pharmaceutical compoundsJournal of Pharmaceutical and Biomedical Analysis, 2004
- Sample Digestion Methods for the Determination of Traces of Precious Metals by Spectrometric TechniquesAnalytical Sciences, 2002
- Separation of osmium from geological materials by solvent extraction for analysis by thermal ionisation mass spectrometryAnalytica Chimica Acta, 1996
- Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometerAnalytical and Bioanalytical Chemistry, 1996
- Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciationJournal of Analytical Atomic Spectrometry, 1994
- Signal enhancement of elements due to the presence of carbon-containing compounds in inductively coupled plasma mass spectrometryAnalytical Chemistry, 1991
- Determination of mercury in seawater at sub-nanogram per liter levelsMarine Chemistry, 1983
- Breakdown of organic mercury compounds by hydrochloric acid—permanganate or bromine monochloride solution for the determination of mercury by cold-vapour atomic absorption spectrometryAnalytica Chimica Acta, 1980