Small intestinal viability assessment using dielectric relaxation spectroscopy and deep learning
Authors:
Open Access
- 28 February 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-10
Abstract
Intestinal ischemia is a serious condition where the surgeon often has to make important but difficult decisions regarding resections and resection margins. Previous studies have shown that 3 h (hours) of warm full ischemia of the small bowel followed by reperfusion appears to be the upper limit for viability in the porcine mesenteric ischemia model. However, the critical transition between 3 to 4 h of ischemic injury can be nearly impossible to distinguish intraoperatively based on standard clinical methods. In this study, permittivity data from porcine intestine was used to analyze the characteristics of various degrees of ischemia/reperfusion injury. Our results show that dielectric relaxation spectroscopy can be used to assess intestinal viability. The dielectric constant and conductivity showed clear differences between healthy, ischemic and reperfused intestinal segments. This indicates that dielectric parameters can be used to characterize different intestinal conditions. In addition, machine learning models were employed to classify viable and non-viable segments based on frequency dependent dielectric properties of the intestinal tissue, providing a method for fast and accurate intraoperative surgical decision-making. An average classification accuracy of 98.7% was obtained using only permittivity data measured during ischemia, and 96.2% was obtained with data measured during reperfusion. The proposed approach allows the surgeon to get accurate evaluation from the trained machine learning model by performing one single measurement on an intestinal segment where the viability state is questionable.Keywords
Funding Information
- Norges Forskningsråd (BioAlert project 296599)
This publication has 37 references indexed in Scilit:
- Dielectric metrology with coaxial sensorsMeasurement Science and Technology, 2007
- Permittivity of Pure Water, at Standard Atmospheric Pressure, over the Frequency Range –25THz and the Temperature Range –100°CJournal of Physical and Chemical Reference Data, 2007
- Evaluation of Ischemic Damage in the Skeletal Muscle with the Use of Electrical PropertiesJournal of Surgical Research, 1998
- Long Short-Term MemoryNeural Computation, 1997
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- Dielectric Spectrogram for Instantaneous Evaluation of Ischemic Injury of the LiverASAIO Journal, 1995
- Complex permittivity of water as a function of frequency and temperatureJournal of Chemical & Engineering Data, 1989
- Dielectric properties of body tissuesClinical Physics and Physiological Measurement, 1987
- Intraoperative Determination of Small Intestinal Viability following Ischemic InjuryAnnals of Surgery, 1981
- SOME HEAT TRANSFER PROBLEMS ASSOCIATED WITH HEATING BY ULTRASOUND, MICROWAVES, OR RADIO FREQUENCY*Annals of the New York Academy of Sciences, 1980