Shapley Value as a Quality Control for Mass Spectra of Human Glioblastoma Tissues
Open Access
Abstract
The automatic processing of high-dimensional mass spectrometry data is required for the clinical implementation of ambient ionization molecular profiling methods. However, complex algorithms required for the analysis of peak-rich spectra are sensitive to the quality of the input data. Therefore, an objective and quantitative indicator, insensitive to the conditions of the experiment, is currently in high demand for the automated treatment of mass spectrometric data. In this work, we demonstrate the utility of the Shapley value as an indicator of the quality of the individual mass spectrum in the classification task for human brain tumor tissue discrimination. The Shapley values are calculated on the training set of glioblastoma and nontumor pathological tissues spectra and used as feedback to create a random forest regression model to estimate the contributions for all spectra of each specimen. As a result, it is shown that the implementation of Shapley values significantly accelerates the data analysis of negative mode mass spectrometry data alongside simultaneous improving the regression models’ accuracy.Keywords
Funding Information
- Ministry of Science and Higher Education of the Russian Federation (0714-2020-0006, 075-00337-20-02)
This publication has 29 references indexed in Scilit:
- Inline cartridge extraction for rapid brain tumor tissue identification by molecular profilingScientific Reports, 2019
- Untangling the Metabolic Reprogramming in Brain Cancer: Discovering Key Molecular Players Using Mass SpectrometryCurrent Topics in Medicinal Chemistry, 2019
- Metrics for evaluating the stability and reproducibility of mass spectraScientific Reports, 2019
- Analysis of human gliomas by swab touch spray-mass spectrometry: applications to intraoperative assessment of surgical margins and presence of oncometabolitesThe Analyst, 2017
- Clinical Application of Ambient Ionization Mass SpectrometryMass Spectrometry, 2017
- Dimensionality reduction of mass spectrometry imaging data using autoencoders2016
- MALDIquant: a versatile R package for the analysis of mass spectrometry dataBioinformatics, 2012
- MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile dataBMC Bioinformatics, 2010
- Building Predictive Models inRUsing thecaretPackage2008
- Prediction error estimation: a comparison of resampling methodsBioinformatics, 2005