Temperature Dependence of the Sensitivity of Silicon Photomultipliers in the Regime of Single-Photon Detection of Ultraviolet Radiation
- 1 May 2021
- journal article
- research article
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 66 (5) , 699-704
Abstract
The temperature dependences of the dark count and efficiency of single-photon detection for two silicon avalanche photodetectors of ultraviolet radiation (OnSemi/SensL MicroFJ-60035 and Hamamatsu VUV4 S13371-6050CQ-02) operating at a wavelength of 277 nm are studied experimentally in the context of development of a new recording camera for the TAIGA-IACT gamma-telescope. It is shown that the main characteristics of these detectors correspond to the manufacturer certification. The signal readout systems have been developed and tested. It is concluded that such detectors are applicable in recording cameras of Cherenkov gamma telescopes.Keywords
This publication has 5 references indexed in Scilit:
- The Application Potential of Silicon Photomultipliers for a Camera of a Small-Size Cherenkov Gamma-Ray Telescope for Reducing the Detection ThresholdTechnical Physics, 2020
- Modelling of SiPM Performance for Detection of Cherenkov Radiation from Extensive Air Showers in UV and Visible Ranges for Application at the TAIGA-IACT TelescopeLatvian Journal of Physics and Technical Sciences, 2020
- TAIGA: A Complex of Hybrid Systems of Cooperating Detectors for Gamma Astronomy and Cosmic Ray Physics in the Tunka ValleyBulletin of the Russian Academy of Sciences: Physics, 2019
- TAIGA observatory: IACT fabrication and tests2019
- TAIGA Gamma Observatory: Status and ProspectsPhysics of Atomic Nuclei, 2018