Clinical evaluation of accelerated breath-held and free-breathing cine cardiac MRI using model-based deep learning reconstruction (SonicDL) in children and young adults
- 28 May 2026
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (10) , 1-11
Abstract
Background Balanced steady-state free-precession (bSSFP) cine imaging is the clinical standard for ventricular function assessment but requires multiple breath-holds, which can be challenging for pediatric and young adult patients. Deep learning (DL)–accelerated cine imaging offers the potential to reduce breath-hold burden, shorten scan time, and enable free-breathing acquisitions. Objective To clinically evaluate a commercially available DL-accelerated cine bSSFP sequence (SonicDL) across multiple acceleration levels and breath-hold/free-breathing configurations, and to assess diagnostic image quality, ventricular volumetric accuracy, and scan time reductions. Materials and methods This retrospective study included 25 patients with pectus excavatum and 15 with cardiomyopathy who underwent conventional cine imaging with breath-hold duration of nine cardiac-cycle interval (9-RR) and SonicDL acquisitions at 4-RR breath-hold, 1-RR breath-hold, and 1-RR free breathing. Diagnostic image quality was independently scored by three expert readers using a 5-point scale. Automated DL-based segmentation provided biventricular volumetric indices, with phase-contrast flow serving as the physiological reference for stroke volume. Statistical analysis included repeated-measures ANOVA, paired tests, ICCs, and Bland–Altman analysis. Results SonicDL significantly reduced scan time 57% (4-RR breath-hold), 79% (1-RR breath-hold), and 87% (1-RR free breathing) compared with 9-RR breath-hold imaging. Diagnostic image quality was highest for 4-RR breath-hold (median 4.50), significantly exceeding other protocols (P2 for most parameters) with limits of agreement typically within ±6 mL/m2. Stroke volumes showed close agreement with phase-contrast flow (biases 1-5 mL/m2) across all protocols. In cardiomyopathy patients, diagnostic image quality was lower overall, but volumetric indices agreement remained within clinically acceptable ranges. Conclusion SonicDL cine bSSFP imaging substantially reduces breath-hold burden and scan time while maintaining diagnostic image quality and close agreement with conventional cine and physiologic flow measurements. The 4-RR breath-hold protocol provided the most favorable balance of acceleration and fidelity, while free-breathing acquisitions offered a practical alternative for patients with limited breath-hold capacity. Graphical abstract The alternative text for this image may have been generated using AI.Keywords
This publication has 21 references indexed in Scilit:
- Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstructionJournal of Cardiovascular Magnetic Resonance, 2024
- Accelerated cardiac magnetic resonance imaging using deep learning for volumetric assessment in childrenPediatric Radiology, 2024
- Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stressScientific Reports, 2024
- Accelerated Cine Cardiac MRI Using Deep Learning‐Based Reconstruction: A Systematic EvaluationJournal of Magnetic Resonance Imaging, 2023
- From Compressed‐Sensing to Deep Learning MR: Comparative Biventricular Cardiac Function Analysis in a Patient CohortJournal of Magnetic Resonance Imaging, 2023
- Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult populationThe International Journal of Cardiovascular Imaging, 2023
- Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validationEuropean Radiology, 2022
- An Adaptive Intelligence Algorithm for Undersampled Knee MRI ReconstructionIEEE Access, 2020
- Simultaneous multislice (SMS) imaging techniquesMagnetic Resonance in Medicine, 2015
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007