Abstract
Electroencephalography (EEG) and magnetoencephalography (MEG) are widely interpreted as direct, non-invasive measures of neural population activity, assuming surrounding tissue and cerebrospinal fluid (CSF) act as passive volume conductors that distorts but do not contribute to signal generation. Using conductive-fluid phantom experiments, structural magnetic resonance imaging, and in vivo EEG and MEG recordings, the present report challenges this assumption. Mechanically driven conductive fluid generated structured, oscillatory, source-localizable electromagnetic signals resembling M/EEG in the absence of neural tissue, and interindividual differences in CSF volume systematically moderated M/EEG signal amplitude. These findings suggest that, at the scales accessed by invasive and non-invasive electrophysiology, electromagnetic and mechanical processes form a coupled system in which contributions of neural currents and fluid motion cannot readily be uniquely separated.
Funding Information
  • Deutsche Forschungsgemeinschaft (PO 1915/7-1)
  • Swiss National Science Foundation (105314_207580)
  • National Institute on Drug Abuse (R21 DA14111)

This publication has 47 references indexed in Scilit: