Performance of Spot Photoscreener in Detecting Amblyopia Risk Factors in Chinese Pre-school and School Age Children Attending an Eye Clinic
Open Access
- 16 February 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0149561
Abstract
To evaluate the effectiveness of Spot photoscreener in detecting amblyopia risk factors meeting 2013 the American Association of Pediatric Ophthalmology and Strabismus (AAPOS) criteria in Chinese preschool and school-age children. One hundred and fifty-five children (310 eyes), aged between 4 to 7 years (5.74 ± 1.2 years) underwent complete ophthalmologic examination, photoscreening, and cycloplegic retinoscopy refraction. The agreement of the results obtained with the photoscreening and retinoscopy was evaluated by linear regression and Bland-Altman plots. The sensitivity and specificity of detecting amblyopia risk factors were calculated based on the AAPOS 2013 guidelines. The overall effectiveness of detecting amblyopia risk factors was analyzed with Receiver Operating Characteristic (ROC) curves. The mean refractive errors measured with the Spot were: spherical equivalent (SE) = 0.70 ± 1.99 D, J0 = 0.87 ± 1.01 D, J45 = 0.09 ± 0.60 D. The mean results from retinoscopy were: SE = 1.19 ± 2.22 D, J0 = 0.77 ± 1.00 D, J45 = -0.02 ± 0.45 D. There was a strong linear agreement between results obtained from those two methods (R2 = 0.88, P<0.01). Bland–Altman plot indicated a moderate agreement of cylinder values between the two methods. Based on the criteria specified by the AAPOS 2013 guidelines, the sensitivity and specificity (in respective order) for detecting hyperopia were 98.31% and 97.14%; for detecting myopia were 78.50% and 88.64%; for detecting astigmatism were 90.91% and 80.37%; for detecting anisometropia were 93.10% and 85.25%; and for detection of strabismus was 77.55% and 88.18%. The refractive values measured from Spot photoscreener showed a moderate agreement with the results from cycloplegic retinoscopy refraction, however there was an overall myopic shift of -0.49D. The performance in detecting individual amblyopia risk factors was satisfactory, but could be further improved by optimizing criteria based on ROC curves.Keywords
This publication has 18 references indexed in Scilit:
- Prevalence of amblyopia and strabismus in Eastern China: results from screening of preschool children aged 36–72 monthsBritish Journal of Ophthalmology, 2015
- Performance of the Plusoptix A09 Photoscreener in Detecting Amblyopia Risk Factors in Chinese Children Attending an Eye ClinicPLOS ONE, 2015
- The effectiveness of the Spot Vision Screener in detecting amblyopia risk factorsJournal of American Association for Pediatric Ophthalmology and Strabismus, 2014
- Calibration and Validation of the 2WIN Photoscreener Compared to the PlusoptiX S12 and the SPOTJournal of Pediatric Ophthalmology & Strabismus, 2014
- Performance of the Spot vision screener for the detection of amblyopia risk factors in childrenJournal of American Association for Pediatric Ophthalmology and Strabismus, 2014
- Guidelines for automated preschool vision screening: A 10-year, evidence-based updateJournal of American Association for Pediatric Ophthalmology and Strabismus, 2013
- Screening for amblyopia risk factors in pre-verbal children using the Plusoptix photoscreener: a cross-sectional population-based studyBritish Journal of Ophthalmology, 2011
- Amblyopia Characterization, Treatment, and ProphylaxisSurvey of Ophthalmology, 2005
- Accuracy of a new photorefractometer in young and adult patientsGraefe's Archive for Clinical and Experimental Ophthalmology, 2005
- The course of moderate amblyopia treated with atropine in children: experience of the amblyopia treatment studyAmerican Journal of Ophthalmology, 2003