Safety Profile of Infinity Deep Brain Stimulation Electrode Placement in a 1.5T Interventional MRI Suite: Consecutive Single-Institution Case Series
- 1 October 2020
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (12) , 2257-2262
Abstract
SUMMARY: “Asleep” deep brain stimulation using general anesthesia and intraoperative MR imaging guidance is considered “off-label” use by current FDA guidelines but is widely used in neurosurgical practice, and excellent safety has been demonstrated using first-generation, omnidirectional electrodes. Safety data for second-generation, directional electrodes in the interventional MR imaging environment have not yet been published. Herein, we report 34 cases of asleep deep brain stimulation using second-generation, directional electrodes in an interventional MR imaging suite at a single institution. Procedural complications and imaging data are described. All patients underwent postoperative MR imaging with fully implanted (“internalized”) electrodes after scalp closure; 4 patients also underwent MR imaging with “externalized” electrodes before scalp closure. No MR imaging–related complications were observed, and procedural complication rates were comparable to prior series. This suggests that the use of second-generation, directional electrodes in the interventional MR imaging environment appears to be safe when following manufacturer-published imaging guidelines.Keywords
This publication has 9 references indexed in Scilit:
- Current and future directions of deep brain stimulation for neurological and psychiatric disordersJournal of Neurosurgery, 2019
- The PROCESS 2018 statement: Updating Consensus Preferred Reporting Of CasE Series in Surgery (PROCESS) guidelinesInternational Journal of Surgery, 2018
- Hemorrhage Detection and Incidence during Magnetic Resonance-Guided Deep Brain Stimulator ImplantationsStereotactic and Functional Neurosurgery, 2017
- Correction of metal-induced susceptibility artifacts for functional MRI during deep brain stimulationNeuroImage, 2017
- Deep brain stimulator implantation in a diagnostic MRI suite: infection history over a 10-year periodJournal of Neurosurgery, 2017
- Clinical outcomes using ClearPoint interventional MRI for deep brain stimulation lead placement in Parkinson’s diseaseJournal of Neurosurgery, 2016
- Intraoperative Functional Magnetic Resonance Imaging for Monitoring the Effect of Deep Brain Stimulation in Patients with Obsessive-Compulsive DisorderStereotactic and Functional Neurosurgery, 2015
- Interventional MRI–guided deep brain stimulation in pediatric dystonia: first experience with the ClearPoint systemJournal of neurosurgery. Pediatrics, 2014
- Clinical outcomes of PD patients having bilateral STN DBS using high-field interventional MR-imaging for lead placementClinical Neurology and Neurosurgery, 2013