Automated determination of drugs in serum by liquid chromatography with column-switching. I. Separation of antiepileptic drugs and metabolites.
Authors:
Open Access
- 1 January 1988
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 34 (1) , 141-144
Abstract
This is a fully automated system for determining six common antiepileptic drugs and two principal metabolites of carbamazepine in serum. It is based on "high-performance" liquid chromatography (HPLC), with column switching. TSKprecolumn BSA-ODS and TSKgel ODS-120A (both from Toyo Soda) were used as the precolumn and analytical column, respectively. The former contains octadecylsilyl resins treated with bovine serum albumin (BSA), and does not adsorb macromolecules such as serum proteins but retains small lipophilic molecules such as antiepileptic drugs. Serum samples are directly injected onto the precolumn. After washing out the serum proteins from the precolumn with sodium phosphate buffer, we switch the column connections to introduce the retained substances onto the analytical column and elute with a step-gradient of acetonitrile/sodium phosphate buffer. The high analytical recovery (95-102%) and the reproducibilities (CV less than 5% within-run) indicate that this system is suitable for use in theraputic drug monitoring in clinical laboratories.Keywords
This publication has 12 references indexed in Scilit:
- Simultaneous determination of eleven antiepileptic compounds in serum by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1984
- Automated analysis of antiepileptic drugs in serum by column-switching high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1983
- Simultaneous very fast liquid-chromatographic analysis of ethosuximide, primidone, phenobarbital, phenytoin, and carbamazepine in serum.Clinical Chemistry, 1983
- Simultaneous Liquid Chromatographic Determination of Chloramphenicol and Antiepileptic Drugs (Phenobarbital, Phenytoin, Carbamazepine, and Primidone) in PlasmaTherapeutic Drug Monitoring, 1983
- Simultaneous High Performance Liquid-Chromatographic Determination of Carbamazepine, Carbamazepine-10, 11-epoxide, Ethosuximide, Phenobarbital, Phenytoin, Primidone and Phenylethylmalonamide in PlasmaClinical Chemistry and Laboratory Medicine (CCLM), 1983
- Improved isocratic liquid-chromatographic simultaneous measurement of phenytoin, phenobarbital, primidone, carbamazepine, ethosuximide, and N-desmethylmethsuximide in serum.Clinical Chemistry, 1982
- A direct injection method of plasma samples onto a reverse phase column for the determination of drugs.Chemical and Pharmaceutical Bulletin, 1982
- ONLINE LIQUID-CHROMATOGRAPHIC ANALYSIS FOR DRUGS IN SERUM WITH THE TECHNICON FAST-LC SYSTEM - PERFORMANCE DATA FOR THEOPHYLLINE AND FOR 4 COMMONLY USED ANTICONVULSANTS AND THEIR METABOLITES1980
- MEASUREMENT OF ANTICONVULSANTS IN SERUM BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY1980
- Rapid micromethod for measuring anticonvulsant drugs in serum by high-performance liquid chromatography.Clinical Chemistry, 1976