pH and water hardness on the efficiency of auxin mimics herbicides
Authors:
- Roberto Costa Avila NetoRNRoberto Costa Avila Neto
- André da Rosa UlguimAUAndré da Rosa Ulguim
- Geovana Facco BarbieriGBGeovana Facco Barbieri
- Rosana Marzari ThomasiRTRosana Marzari Thomasi
- Eduardo BortolinEBEduardo Bortolin
- Eduard Mroginski LeichtweisELEduard Mroginski Leichtweis
- Adriano Arrué MeloAMAdriano Arrué Melo
Open Access
- 1 January 2024
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 54 (4) , e20230005
Abstract
Carrier water quality is one of the main characteristics for an efficient and safe spraying of pesticides. Overall related to the levels of pH and hardness. The objective was to evaluate the interaction between water pH and storage time of the spray, containing 2,4-D amine, 2,4-D choline and dicamba, on the visible efficacy in Ipomoea triloba, Bidens pilosa, Amaranthus viridis; and water hardness on I. triloba. Three studies were carried out in a greenhouse. Study 1 with a 3x5 factorial, which factor A being pH of 2, 6 and 10 and factor B being 0, 2, 6, 24 and 36 hours of application after the mixture. Study 2 was a 3x5 factorial for each herbicide, whith factor A being the levels of pH (2, 6 and 10) and factor B being 0, 6, 12, 24 and 48 hours of application after the mixture. The study 3 is a 3x7 factorial, with factor A being the herbicides and factor B levels of water hardness: 0, 65, 125, 250, 500, 750 and 1000 parts per million. The pH of all solutions remained stable for 48 hours after preparation. However, did not interfere in efficacy of dicamba in I. triloba. Also, longer time between preparing the spray with 2,4-D formulations and application caused reduction efficacy on I. triloba. Also, the level of water hardness decreased control on I. triloba. The pH of carrier water did not affect efficacy of 2,4-D and dicamba on the weeds; however, longer time of the spray application reduce the visible efficacy.Keywords
This publication has 25 references indexed in Scilit:
- Glufosinate Efficacy as Influenced by Carrier Water pH, Hardness, Foliar Fertilizer, and Ammonium SulfateWeed Technology, 2016
- Influence of Carrier Water pH, Hardness, Foliar Fertilizer, and Ammonium Sulfate on Mesotrione EfficacyWeed Technology, 2016
- Divalent Cations in Spray Water Influence 2,4-D Efficacy on Dandelion (Taraxacum officinale) and Broadleaf Plantain (Plantago major)Weed Technology, 2016
- Dose-Response Analysis Using RPLOS ONE, 2015
- The effect of hard water, spray solution storage time, and ammonium sulfate on glyphosate efficacy and yield of glyphosate-resistant cornCanadian Journal of Plant Science, 2014
- The Influence of Carrier Water pH and Hardness on Saflufenacil Efficacy and SolubilityWeed Technology, 2013
- The Effect of Cations and Ammonium Sulfate on the Efficacy of Dicamba and 2,4-DWeed Technology, 2013
- Effect of ammonium sulfate and water hardness on glyphosate and glufosinate activity in cornCanadian Journal of Plant Science, 2011
- How long can a herbicide remain in the spray tank without losing efficacy?Crop Protection, 2009
- Increasing the Biological Activity of Weak Acid Herbicides by Increasing and Decreasing the pH of the Spray MixtureJournal of ASTM International, 2005