Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
Authors:
Open Access
- 11 May 2023
- journal article
- review article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-20
Abstract
Background: Rigid fixation, represented by titanium rods, is a widely used fixation technique for lumbar fusion. However, this technique carries the risk of degeneration of adjacent segments. In recent years, the semi-rigid fixation technique represented by PEEK rods has gradually matured, and its effectiveness has been verified by numerous studies. The aim of this study was to systematically evaluate the effectiveness of these two fixation modalities in posterior lumbar fusion surgery. Methods: Studies meeting the inclusion criteria were searched in PubMed, Cochrane Library, ScienceDirect, Embase, CNKI, and Wanfang databases. After data extraction and quality assessment of included studies, meta-analysis was performed using STATA 15.1 software. The protocol for this systematic review was registered on INPLASY (2021110049) and is available in full on the inplasy.com (https://inplasy.com/inplasy-2021-11-0049/). Results: Fifteen relevant studies were finally included, including eight prospective studies and seven retrospective studies. The results of meta-analysis showed that in ODI (P = 0.000), JOA score (P = 0.017), VAS score for lower limb pain (P = 0.027), fusion rate of bone graft at week 12 (P = 0.001), fusion rate of bone graft at last follow-up (P = 0.028), there was a statistical difference between the two groups. The PEEK rod group was superior to the titanium rod group in the above aspects. While in VAS score for LBP (P = 0.396), there was no statistical difference between the two groups. Conclusion: Both PEEK rods and titanium rods are effective fixation materials in lumbar fusion surgery. PEEK rods may be superior to titanium rods in improving postoperative function and improving bone graft fusion rates. However, given the limitations of this study, whether these conclusions are applicable needs further research.Keywords
This publication has 30 references indexed in Scilit:
- Posterior lumbar fusion by peek rods in degenerative spine: preliminary report on 30 casesEuropean Spine Journal, 2012
- The Cochrane Collaboration's tool for assessing risk of bias in randomised trialsBMJ, 2011
- Biomechanical Assessment of a PEEK Rod System for Semi-Rigid Fixation of Lumbar Fusion ConstructsJournal of Biomechanical Engineering, 2011
- Dynamic stabilization versus fusion for treatment of degenerative spine conditionsEvidence-Based Spine-Care Journal, 2011
- Biomechanics of polyaryletherketone rod composites and titanium rods for posterior lumbosacral instrumentationJournal of Neurosurgery: Spine, 2010
- The Mechanical Effect of Commercially Pure Titanium and Polyetheretherketone Rods on Spinal Implants at the Operative and Adjacent LevelsSpine, 2010
- Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixationThe Spine Journal, 2009
- Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devicesBiomedical Materials, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion–A Finite Element StudySpine, 2006