Free‐breathing fetal cardiac MRI with doppler ultrasound gating, compressed sensing, and motion compensation
Open Access
- 22 June 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (1) , 260-272
Abstract
Background: Fetal cardiovascular MRI complements ultrasound to assess fetal cardiovascular pathophysiology.Purpose: To develop a free‐breathing method for retrospective fetal cine MRI using Doppler ultrasound (DUS) cardiac gating and tiny golden angle radial sampling (tyGRASP) for accelerated acquisition capable of detecting fetal movements for motion compensation.Study Type: Feasibility study.Subjects: Nine volunteers (gestational week 34–40). Short‐axis and four‐chamber views were acquired during maternal free‐breathing and breath‐hold.Field Strength/Sequence: 1.5T cine balanced steady‐state free precession.Assessment: A self‐gated reconstruction method was improved for clinical application by using 1) retrospective DUS gating, and 2) motion detection and rejection/correction algorithms for compensating for fetal motion. The free‐breathing reconstructions were qualitatively and quantitatively assessed, and DUS‐gating was compared with self‐gating in breath‐hold reconstructions. A scoring of 1–4 for overall image quality, cardiac, and extracardiac diagnostic quality was used.Statistical Tests: Friedman's test was used to assess differences in qualitative scoring between observers. A Wilcoxon matched‐pairs signed rank test was used to assess differences between breath‐hold and free‐breathing acquisitions and between observers' quantitative measurements.Results: In all cases, 111 free‐breathing and 145 breath‐hold acquisitions, the automatically calculated DUS‐based cardiac gating signal provided reconstructions of diagnostic quality (median score 4, range 1–4). Free‐breathing did not affect the DUS‐based cardiac gated retrospective radial reconstruction with respect to image or diagnostic quality (all P > 0.06). Motion detection with rejection/correction in k‐space produced high‐quality free‐breathing DUS‐based reconstructions [median 3, range (2–4)], whereas free‐breathing self‐gated methods failed in 80 out of 88 cases to produce a stable gating signal.Data Conclusion: Free‐breathing fetal cine cardiac MRI based on DUS gating and tyGRASP with motion compensation yields diagnostic images. This simplifies acquisition for the pregnant woman and thus could help increase fetal cardiac MRI acceptance in the clinic.Level of Evidence: 2Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:260–272.Keywords
This publication has 34 references indexed in Scilit:
- Cardiac MRI of the fetal heart using a novel triggering method: Initial results in an animal modelJournal of Magnetic Resonance Imaging, 2012
- Retrospective reconstruction of high temporal resolution cine images from real‐time MRI using iterative motion correctionMagnetic Resonance in Medicine, 2011
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- Design and validation of Segment - freely available software for cardiovascular image analysisBMC Medical Imaging, 2010
- A software channel compression technique for faster reconstruction with many channelsMagnetic Resonance Imaging, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- No-Reference Image Quality Metrics for Structural MRINeuroinformatics, 2006
- Self‐gated cardiac cine MRIMagnetic Resonance in Medicine, 2003
- Nonuniform fast fourier transforms using min-max interpolationIEEE Transactions on Signal Processing, 2003
- Normal fetal cardiac measurements derived by cross‐sectional echocardiographyUltrasound in Obstetrics & Gynecology, 1992