Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes
Authors:
- 25 July 2015
- journal article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 9 (1) , 37-43
Abstract
Our purpose in the current study was to model an X-ray CT scanner with the Monte Carlo (MC) method for gel dosimetry. In this study, a conventional CT scanner with one array detector was modeled with use of the MCNPX MC code. The MC calculated photon fluence in detector arrays was used for image reconstruction of a simple water phantom as well as polyacrylamide polymer gel (PAG) used for radiation therapy. Image reconstruction was performed with the filtered back-projection method with a Hann filter and the Spline interpolation method. Using MC results, we obtained the dose–response curve for images of irradiated gel at different absorbed doses. A spatial resolution of about 2 mm was found for our simulated MC model. The MC-based CT images of the PAG gel showed a reliable increase in the CT number with increasing absorbed dose for the studied gel. Also, our results showed that the current MC model of a CT scanner can be used for further studies on the parameters that influence the usability and reliability of results, such as the photon energy spectra and exposure techniques in X-ray CT gel dosimetry.Keywords
This publication has 21 references indexed in Scilit:
- Polymer gel dosimetry using x-ray computed tomography: investigation of the effect of reconstruction techniqueJournal of Physics: Conference Series, 2010
- Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applicationsReports of Practical Oncology and Radiotherapy, 2010
- Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetryPhysics in Medicine & Biology, 2010
- Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CTPhysics in Medicine & Biology, 2009
- Adaptive mean filtering for noise reduction in CT polymer gel dosimetryMedical Physics, 2007
- Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CTPhysics in Medicine & Biology, 2005
- Technical considerations for implementation of x-ray CT polymer gel dosimetryPhysics in Medicine & Biology, 2005
- Image filtering for improved dose resolution in CT polymer gel dosimetryMedical Physics, 2003
- CT gel dosimetry technique: Comparison of a planned and measured 3D stereotactic dose volumeJournal of Applied Clinical Medical Physics, 2002
- Some sources of artefact in computed tomographyPhysics in Medicine & Biology, 1980