Ray-tracing analysis of intraocular lens power in situ
Authors:
- Thomas OlsenTOThomas Olsen
- Mikkel FundingMFMikkel Funding
- 1 April 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (4) , 641-647
Abstract
To describe a method for back-solving the power of an intraocular lens (IOL) in situ based on laser biometry and ray-tracing analysis of the pseudophakic eye. University Eye Clinic, Aarhus Hospital, Aarhus, Denmark. Evaluation of diagnostic test or technology. This study comprised pseudophakic eyes with an IOL power ranging from -2.00 to +36.00 diopters (D). Preoperatively, the corneal radius was measured with conventional autokeratometry and the axial length (AL) with optical biometry. After surgery, the position of the IOL was recorded using laser interferometry. Based on the postoperative refraction and the biometric measurements, a ray-tracing analysis was performed back-solving for the power of the IOL in situ. The analysis was performed assuming pupil diameters from 0.0 to 8.0 mm with and without correction for the Stiles-Crawford effect. The study evaluated 767 pseudophakic eyes (583 patients). Assuming a 3.0 mm pupil, the mean prediction error between the labeled and the calculated IOL power (± 1 standard deviation [SD]) was -0.26 D ± 0.65 (SD) (range -2.4 to +1.8 D). The prediction error showed no bias with IOL power or with AL. The calculated IOL power depended on the assumed pupil size and the Stiles-Crawford effect. However, the latter had a modulatory effect on the prediction error for large pupil diameters (>5.0 mm) only. The optics of the pseudophakic eye can be accurately described using exact ray tracing and modern biometric techniques.Keywords
This publication has 10 references indexed in Scilit:
- The shape of the anterior and posterior surface of the aging human corneaVision Research, 2006
- Calibration of axial length measurements with the Zeiss IOLMasterJournal of Cataract & Refractive Surgery, 2005
- Pseudophakic correction factors for optical biometryGraefe's Archive for Clinical and Experimental Ophthalmology, 2001
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Partial coherence interferometry: a novel approach to biometry in cataract surgeryAmerican Journal of Ophthalmology, 1998
- On the Stiles‐Crawford effect and ocular imageryActa Ophthalmologica, 1993
- Normal variations of the posterior corneal surfaceActa Ophthalmologica, 1992
- Comparison of the SRK/T formula and other theoretical and regression formulasJournal of Cataract & Refractive Surgery, 1990
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Measuring the power of an in situ intraocular lens with the keratometerJournal of Cataract & Refractive Surgery, 1988