A multiple source model for 6 MV photon beam dose calculations using Monte Carlo
Authors:
- 17 April 2001
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (5) , 1407-1427
Abstract
A multiple source model (MSM) for the 6 MV beam of a Varian Clinac 2300 C/D was developed by simulating radiation transport through the accelerator head for a set of square fields using the GEANT Monte Carlo (MC) code. The corresponding phase space (PS) data enabled the characterization of 12 sources representing the main components of the beam defining system. By parametrizing the source characteristics and by evaluating the dependence of the parameters on field size, it was possible to extend the validity of the model to arbitrary rectangular fields which include the central 3 x 3 cm2 field without additional precalculated PS data. Finally, a sampling procedure was developed in order to reproduce the PS data. To validate the MSM, the fluence, energy fluence and mean energy distributions determined from the original and the reproduced PS data were compared and showed very good agreement. In addition, the MC calculated primary energy spectrum was verified by an energy spectrum derived from transmission measurements. Comparisons of MC calculated depth dose curves and profiles, using original and PS data reproduced by the MSM, agree within 1% and 1 mm. Deviations from measured dose distributions are within 1.5% and 1 mm. However, the real beam leads to some larger deviations outside the geometrical beam area for large fields. Calculated output factors in 10 cm water depth agree within 1.5% with experimentally determined data. In conclusion, the MSM produces accurate PS data for MC photon dose calculations for the rectangular fields specified.Keywords
This publication has 38 references indexed in Scilit:
- Simple beam models for Monte Carlo photon beam dose calculations in radiotherapyMedical Physics, 2000
- Photon beam characterization and modelling for Monte Carlo treatment planningPhysics in Medicine & Biology, 2000
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999
- The flatness of Siemens linear accelerator x‐ray fieldsMedical Physics, 1999
- Collimator scatter in photon therapy beamsMedical Physics, 1995
- Reconstruction of 12 MV bremsstrahlung spectra from measured transmission data by direct resolution of the numeric system AF=TMedical Physics, 1995
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- On the field-size dependence of relative output from a linear acceleratorMedical Physics, 1992
- A pencil beam model for photon dose calculationMedical Physics, 1992
- A photon dose distribution model employing convolution calculationsMedical Physics, 1985