Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight?
Authors:
- 19 March 2013
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 23 (7) , 1855-1861
Abstract
To compare total body weight (TBW), lean body weight (LBW) and body surface area (BSA) for the adjustment of the iodine dose required for contrast-enhanced multi-detector computed tomography (MDCT) of the aorta and the liver. One hundred and three patients undergoing MDCT of the abdomen were randomised into three groups: the TBW group receiving 0.6 g iodine/kg of TBW (n = 33), the LBW group receiving 0.75 g iodine/kg of LBW (n = 35) and the BSA group receiving 22 g iodine/m2 (n = 35). ∆HU (increases in CT value) per gram of iodine (∆HU/g) and adjusted maximum hepatic enhancement (adjusted MHE; ∆HU/[g iodine/kg]) correlated with three groups using linear regressions. Correlation coefficients of ∆HU/g were 0.67 (TBW), 0.86 (LBW) and 0.85 (BSA) for the aorta, and 0.74 (TBW), 0.77 (LBW) and 0.84 (BSA) for the liver. Adjusted MHE was constant at 70.2 with LBW and at 2.69 with BSA, but correlated positively with TBW (r = 0.58, P < 0.001). Iodine load may need to be tailored by LBW or BSA in contrast enhanced MDCT of the abdomen. BSA is a simple and feasible index for the determination of iodine dose in individual patients. • Optimisation of enhancement is very important for high quality MDCT. • Iodine dose is best adjusted according to LBW or BSA. • BSA may be adopted because calculation is simple. • Iodine dose of 0.712 g/kg LBW/18.6 g/m 2 BSA gives 50 HU hepatic enhancement.Keywords
This publication has 34 references indexed in Scilit:
- Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCTEuropean Radiology, 2010
- MDCT of the Liver and Hypervascular Hepatocellular Carcinomas: Optimizing Scan Delays for Bolus-Tracking Techniques of Hepatic Arterial and Portal Venous PhasesAmerican Journal of Roentgenology, 2006
- Hepatic Metastases: Detection with Multi–Detector Row CT, SPIO-enhanced MR Imaging, and Both Techniques CombinedRadiology, 2006
- Optimizing Scan Delays of Fixed Duration Contrast Injection in Contrast-Enhanced Biphasic Multidetector-Row CT for the Liver and the Detection of Hypervascular Hepatocellular CarcinomaJournal of Computer Assisted Tomography, 2005
- Multi–Detector Row Helical CT in Preoperative Assessment of Small (≤1.5 cm) Liver Metastases: Is Thinner Collimation Better?Radiology, 2002
- Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi–Detector Row Helical CTRadiology, 2002
- Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material—A Prospective Randomized StudyRadiology, 2000
- Effect of Injection Rate of Contrast Medium on Pancreatic and Hepatic Helical CTRadiology, 1999
- Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement.Radiology, 1995
- Hepatic helical CT: contrast material injection protocol.Radiology, 1994