Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantation
Authors:
- Mayank A. NanavatyMayank A. Nanavaty
- Abhay R. VasavadaAVAbhay R. Vasavada
- Anil S. PatelAPAnil S. Patel
- Shetal M. RajSRShetal M. Raj
- Tejas H. DesaiTDTejas H. Desai
- 1 July 2006
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (7) , 1091-1097
Abstract
To analyze factors contributing to uncorrected visual acuity of at least 6/12 for distance and at least J4 for near (pseudoaccommodation) after monofocal intraocular lens (IOL) implantation. Iladevi Cataract and IOL Research Center, Ahmedabad, India. In a case-controlled study of 30 eyes (30 patients) that had phacoemulsification, those with pseudoaccommodation were assigned to cases and 30 eyes (30 patients) without pseudoaccommodation were designated as controls. Controls were matched by identical best corrected visual acuity, age, and postoperative duration. Subjective refraction was done with retinoscopy. Factors analyzed included corneal astigmatism, pupil size, axial IOL movement, amplitude of accommodation, axial length (AL), and age. Corneal astigmatism was noted on topography and interpreted as against the rule (ATR) (180 +/- 15 degrees), with the rule (WTR) (90 +/- 15 degrees), and oblique (OB) (45/135 +/- 30 degrees). Pupil size was noted on topographic display and AL and anterior chamber depth (ACD) on immersion A-scan. The axial IOL movement was calculated as the difference in ACD after instillation of cyclopentolate 1% (Cyclopent) and subsequently pilocarpine nitrate 2% (Carpinol) at separate visits, and amplitude of accommodation was measured with static and dynamic retinoscopy. Multivariate logistic regression and odds ratio with 95% confidence intervals were determined. Mean spherical equivalent was -0.45 +/- 0.63 diopter (D) in cases and -0.35 +/- 0.83 D (P = .61) in controls. Multivariate logistic regression in cases versus controls: corneal astigmatism (ATR versus WTR and OB collectively): 10.19 [1.8,57.44], P = .009; pupil size: 0.45 [0.07,2.71], P = .38; axial IOL movement: 1.39 [0.51,0.77], P = .514; amplitude of accommodation: 2.95 [0.93,9.3], P = .065; AL: 0.55 [0.29,1.02], P = .058; and age: 0.98 [0.5,1.95], P = .963. The study suggests a significant role of ATR corneal astigmatism in good uncorrected distance and near vision after monofocal IOL implantation.Keywords
This publication has 31 references indexed in Scilit:
- Stimulus-driven versus pilocarpine-induced biometric changes in pseudophakic eyesOphthalmology, 2005
- Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lensesOphthalmology, 2004
- Effect of haptic design on change in axial lens position after cataract surgeryJournal of Cataract & Refractive Surgery, 2004
- Step-down techniqueJournal of Cataract & Refractive Surgery, 2003
- Relationship between apparent accommodation and corneal multifocality in pseudophakic eyesOphthalmology, 1999
- Pseudoaccommodation: BioComFoldversus a foldable silicone intraocular lensJournal of Cataract & Refractive Surgery, 1999
- Optimal postoperative refraction for good unaided near and distance vision with monofocal intraocular lenses.British Journal of Ophthalmology, 1992
- Apparent accommodation in pseudophakic eyesActa Ophthalmologica, 1990
- Pseudophakic accommodation? A study of the stability of capsular bag supported, one piece, rigid tripod, or soft flexible implants.British Journal of Ophthalmology, 1990
- Myopic astigmatism a substitute for accommodation in pseudophakiaDocumenta Ophthalmologica, 1981