Purpose: Water removal is one of the computational bottlenecks in the processing of high‐resolution MRSI data. The purpose of this work is to propose an approach to reduce the computing time required for water removal in large MRS data.Methods: In this work, we describe a singular value decomposition–based approach that uses the partial position‐time separability and the time‐domain linear predictability of MRSI data to reduce the computational time required for water removal. Our approach arranges MRS signals in a Casorati matrix form, applies low‐rank approximations utilizing singular value decomposition, removes residual water from the most prominent left‐singular vectors, and finally reconstructs the water‐free matrix using the processed left‐singular vectors.Results: We have demonstrated the effectiveness of our proposed algorithm for water removal using both simulated and in vivo data. The proposed algorithm encompasses a pip‐installable tool ( https://pypi.org/project/CSVD/), available on GitHub ( https://github.com/amirshamaei/CSVD), empowering researchers to use it in future studies. Additionally, to further promote transparency and reproducibility, we provide comprehensive code for result replication.Conclusions: The findings of this study suggest that the proposed method is a promising alternative to existing water removal methods due to its low processing time and good performance in removing water signals.Keywords
Funding Information
- Akademie Věd České Republiky (RVO:68081731)
This publication has 22 references indexed in Scilit:
- Denoising of diffusion MRI using random matrix theoryNeuroImage, 2016
- Proton MRS and MRSI of the brain without water suppressionProgress in Nuclear Magnetic Resonance Spectroscopy, 2015
- Removal of nuisance signals from limited and sparse 1H MRSI data using a union‐of‐subspaces modelMagnetic Resonance in Medicine, 2015
- The Optimal Hard Threshold for Singular Values is \(4/\sqrt {3}\)IEEE Transactions on Information Theory, 2014
- Denoising MR Spectroscopic Imaging Data With Low-Rank ApproximationsIEEE Transactions on Biomedical Engineering, 2013
- Improved Lanczos Algorithms for Blackbox MRS Data QuantitationJournal of Magnetic Resonance, 2002
- Optimization of Residual Water Signal Removal by HLSVD on Simulated Short Echo Time Proton MR Spectra of the Human BrainJournal of Magnetic Resonance, 2001
- Fast Removal of Residual Water in Proton SpectraJournal of Magnetic Resonance, 1998
- Differentiation of metabolic concentrations between gray matter and white matter of human brain by in vivo1H magnetic resonance spectroscopyMagnetic Resonance in Medicine, 1998
- Absolute concentrations of metabolites in the adult human brain in vivo: quantification of localized proton MR spectra.Radiology, 1993