The suitability of hexyl cinnamic aldehyde as a calibrant for the murine local lymph node assay
Authors:
- 1 June 2001
- journal article
- research article
- Published by Wiley in Contact Dermatitis
- Vol. 44 (6) , 357-361
Abstract
The murine local lymph node assay (LLNA) for the prospective identification of contact allergens assesses skin sensitization potential as a function of proliferative activity induced in lymph nodes draining the site of topical exposure to test chemical. This method has been endorsed recently as a stand alone test for the identification of contact allergens. We have now examined the suitability of hexyl cinnamic aldehyde (HCA), a recommended positive control for skin sensitization testing, as a calibrant for comparing the consistency of LLNA responses with time, and between laboratories, and thus for the routine assessment of assay reliability. Standard LLNAs were performed with CBA strain mice in 3 independent laboratories over a period of 8 years. Dose‐response curves were used to derive mathematically the EC3 value (the estimated concentration of chemical necessary to cause a stimulation index (SI) of 3 compared with proliferation induced by concurrent vehicle controls). In each laboratory, 6 separate experiments were conducted using a single concentration of HCA (25%). Very similar stimulation indices were achieved, with mean values of 9.0, 6.5 and 6.6 recorded. A total of 10 dose‐response experiments were performed independently in the 3 laboratories and these revealed that there was very little inter‐laboratory, or temporal, variation in EC3 values. These data confirm that HCA responses in the LLNA are very stable and demonstrate that HCA provides a suitable calibrant for determining assay sensitivity and performance.Keywords
This publication has 15 references indexed in Scilit:
- Local lymph node assay: Validation assessment for regulatory purposesDermatitis®, 2000
- Local lymph node assay: use in hazard and risk assessmentJournal of Applied Toxicology, 1999
- A comparison of statistical approaches to the derivation of EC3 values from local lymph node assay dose responsesJournal of Applied Toxicology, 1999
- Temporal stability of local lymph node assay responses to hexyl cinnamic aldehydeJournal of Applied Toxicology, 1998
- Contact sensitization: A new approach to risk assessmentHuman and Ecological Risk Assessment: An International Journal, 1997
- An international evaluation of the murine local lymph node assay and comparison of modified proceduresToxicology, 1995
- The local lymph node assay: developments and applicationsToxicology, 1994
- Examination of the local lymph node assay for use in contact sensitization risk assessmentFundamental and Applied Toxicology, 1992
- The murine local lymph node assay: A commentary on collaborative studies and new directionsFood and Chemical Toxicology, 1992
- Use of Ranks in One-Criterion Variance AnalysisJournal of the American Statistical Association, 1952