Orthopedic implant of a polyhydroxybutyrate (PHB) and hydroxyapatite composite in cats
- 1 August 2011
- journal article
- research article
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 13 (8) , 546-552
Abstract
The purpose of this study was to evaluate the tissue response to a 70% polyhydroxybutyrate and 30% hydroxyapatite composite in the form of a bone implant, placed intracortically in the distal metaphyseal of the right femur, and subcutaneous implants in cats. Samples of the composite were implanted subcutaneously in the dorsolumbar region and the distal metaphyseal region of the right femur of the animals. The study used 12 neutered adult mixed breed cats, weighing an average of 3.5 kg. The cats were randomly divided into three groups: GI, GII and GIII, according to the length of the assessment period. The assessments of their subcutaneous and bone tissues were performed at 15, 30 and 45 days and at 30, 60 and 90 days, respectively. The subcutaneous and bone reactions to the composites were characterized by granulomatous inflammation with a predominance of macrophages and giant cells. The results showed that the composites triggered a chronic local inflammatory response, despite their clinical acceptance.Keywords
This publication has 18 references indexed in Scilit:
- Avaliação mecânica da placa de compósito de poli-hidroxibutirato e hidroxiapatita em modelos ósseos de gatoArquivo Brasileiro de Medicina Veterinária e Zootecnia, 2010
- Management of fractures of the long bones of eight cats using external skeletal fixation and a tied-in intra-medullary pin with a resin-acrylic barNew Zealand Veterinary Journal, 2007
- Mesenchymal stem cell ingrowth and differentiation on coralline hydroxyapatite scaffoldsBiomaterials, 2007
- Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineeringBiomaterials, 2006
- Regeneration of trabecular bone using porous ceramicsCurrent Opinion in Solid State and Materials Science, 2003
- Long-term histological evaluation of hydroxyapatite ceramics in humansBiomaterials, 1995
- Tissue response and in vivo degradation of selected polyhydroxyacids: Polylactides (PLA), poly(3‐hydroxybutyrate) (PHB), and poly(3‐hydroxybutyrate‐co‐3‐hydroxyvalerate) (PHB/VA)Journal of Biomedical Materials Research, 1993
- Development of a degradable composite for orthopaedic use: in vivo biomechanical and histological evaluation of two bioactive degradable composites based on the polyhydroxybutyrate polymerBiomaterials, 1992
- In vitro and in vivo evaluation of polyhydroxybutyrate and of polyhydroxybutyrate reinforced with hydroxyapatiteBiomaterials, 1991
- Bioreactions at the tissue/ hydroxyapatite interfaceBiomaterials, 1985