Abstract
Hyperpolarized (HP) 129Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP 129Xe MRI as outcome measures in multi‐site clinical trials across a range of pulmonary disorders. Until recently, HP 129Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies. To promote uniformity and adoption of HP 129Xe MRI more widely in translational research, multi‐site trials, and ultimately clinical practice, this position paper from the 129Xe MRI Clinical Trials Consortium (https://cpir.cchmc.org/XeMRICTC) recommends standard protocols to harmonize methods for image acquisition in HP 129Xe MRI. Recommendations are described for the most common HP gas MRI techniques—calibration, ventilation, alveolar‐airspace size, and gas exchange—across MRI scanner manufacturers most used for this application. Moreover, recommendations are described for 129Xe dose volumes and breath‐hold standardization to further foster consistency of imaging studies. The intention is that sites with HP 129Xe MRI capabilities can readily implement these methods to obtain consistent high‐quality images that provide regional insight into lung structure and function. While this document represents consensus at a snapshot in time, a roadmap for technical developments is provided that will further increase image quality and efficiency. These standardized dosing and imaging protocols will facilitate the wider adoption of HP 129Xe MRI for multi‐site pulmonary research.Keywords
This publication has 117 references indexed in Scilit:
- Chronic Obstructive Pulmonary Disease: Safety and Tolerability of Hyperpolarized129Xe MR Imaging in Healthy Volunteers and PatientsRadiology, 2012
- Relaxation of hyperpolarized 129Xe in a deflating polymer bagJournal of Magnetic Resonance, 2011
- Lung morphometry with hyperpolarized 129Xe: Theoretical backgroundMagnetic Resonance in Medicine, 2011
- Hyperpolarized Xenon‐129 gas‐exchange imaging of lung microstructure: First case studies in subjects with obstructive lung diseaseJournal of Magnetic Resonance Imaging, 2011
- Diffusion‐weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary diseaseMagnetic Resonance in Medicine, 2010
- Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in HumansPLOS ONE, 2010
- Quantification of lung microstructure with hyperpolarized 3He diffusion MRIJournal of Applied Physiology, 2009
- Calibration of RF transmitter voltages for hyperpolarized gas MRIMagnetic Resonance in Medicine, 2008
- Human Pulmonary Imaging and Spectroscopy with Hyperpolarized 129Xe at 0.2TAcademic Radiology, 2008
- Imaging alveolar–capillary gas transfer using hyperpolarized 129 Xe MRIProceedings of the National Academy of Sciences, 2006