Abstract
Although SiC-MOSFET has shown significant advantages on switching performance compared to traditional Si-IGBT, the dynamic loss of SiC-MOSFET devices at hard switching rises quickly with the increment of the switching frequency. To further push the power density of SiC-MOSFET inverter, Zero-Voltage-Switching (ZVS) technique is introduced. In this paper the loss distributions, conversion efficiencies and volumes of passive components of both a 20 kW hard switching SiC-MOSFET inverter and a 20 kW ZVS SiC-MOSFET inverter have been compared under switching frequency ranging from 50 kHz to 300 kHz. Meanwhile, a new metric called “Efficiency Stiffness” is proposed to compare different inverters with respect to the efficiency performance vs. switching frequency characteristics. In addition, a power module including seven SiC-MOSFET bare dies with low stray inductance is designed for ZVS inverter instead of the existing seven discrete TO-247 package SiC-MOSFETs in order to reduce the voltage overshoots on the switches. Besides, in order to reduce the power loss of the resonant inductor caused by large amplitude of current at hundreds of kHz excitation frequency, design of the inductor with distributed air-gap and winding are studied. A 20 kW SiC MOSFET ZVS grid inverter prototype is built to verify the proposed design.
Funding Information
  • National Natural Science Foundation of China (51337009)

This publication has 33 references indexed in Scilit: