Loop-Based Multiple Heart-Cutting Two-Dimensional Liquid Chromatography for Target Analysis in Complex Matrices
Authors:
- 21 April 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (10) , 5310-5317
Abstract
Loop-based multiple heart-cutting (MHC) two-dimensional liquid chromatography (2D-LC) is presented as a solution to quantify target components in complex matrices, such as additives in polymers, at very high chromatographic resolution. The determination of hexabromocyclododecane (HBCD) in polystyrene (PS) is described. One dimensional (1D) LC analysis with UV detection did not allow quantitation of the main isomers of HBCD due to peak overlap with polymer components. MHC 2D-LC analysis provided the separation power, accuracy, and repeatability needed for quantitative analysis of the additives of interest. Heart-cuts from peaks of the 1D-chromatogram or entire regions of interest are sampled into loops, where they remain parked until their sequential reinjection onto the second dimension (2D) column. A column set consisting of phenyl (1D) and C18 (2D) stationary phases gave baseline separation in 2D between HBCD and PS background. Linearity for spiked polymer samples was achieved over a range of 0.02–1.00 wt % HBCD relative to the amount of polymer. The limit of quantitation was estimated at 0.01 wt % HBCD in PS. A peak area RSD of 0.7% obtained for ten replicates of a real sample demonstrated excellent repeatability of the analysis. MHC 2D-LC is an elegant solution for quantitative analyses of difficult-to-separate samples when conventional 1D separation fails.Keywords
Funding Information
- Dow Chemical Company
This publication has 25 references indexed in Scilit:
- Application of Heart-Cutting 2D-LC for the Determination of Peak Purity for a Chiral Pharmaceutical Compound by HPLCChromatographia, 2012
- Selective comprehensive multidimensional separation for resolution enhancement in high performance liquid chromatography. Part II: ApplicationsJournal of Chromatography A, 2012
- Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentationJournal of Chromatography A, 2012
- Quantitative Characterization of Solid Epoxy Resins Using Comprehensive Two Dimensional Liquid Chromatography Coupled with Electrospray Ionization-Time of Flight Mass SpectrometryAnalytical Chemistry, 2009
- Comprehensive multidimensional liquid chromatography: Theory and applicationsJournal of Chromatography A, 2008
- Fast, comprehensive two-dimensional liquid chromatographyJournal of Chromatography A, 2007
- Relevance of π–π and dipole–dipole interactions for retention on cyano and phenyl columns in reversed-phase liquid chromatographyJournal of Chromatography A, 2005
- Impact of methanol and acetonitrile on separations based on π–π interactions with a reversed-phase phenyl columnJournal of Chromatography A, 2005
- One- and Two-Dimensional Chromatographic Analysis of Alcohol EthoxylatesAnalytical Chemistry, 1998
- Automated instrumentation for comprehensive two-dimensional high-performance liquid chromatography of proteinsAnalytical Chemistry, 1990