New Microfluidic-Based Sampling Procedure for Overcoming the Hematocrit Problem Associated with Dried Blood Spot Analysis
- 30 January 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (4) , 2068-2071
Abstract
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.Keywords
Funding Information
- Service de la Promotion Economique et du Commerce, Canton de Vaud
This publication has 20 references indexed in Scilit:
- Simultaneous LC–MS/MS Quantification of P-Glycoprotein and Cytochrome P450 Probe Substrates and Their Metabolites in DBS and PlasmaBioanalysis, 2014
- Dried Matrix on Paper Disks: The Next Generation Dbs Microsampling Technique For Managing The Hematocrit Effect in Dbs AnalysisBioanalysis, 2012
- Managing The Effect of Hematocrit on Dbs Analysis in A Regulated EnvironmentBioanalysis, 2012
- LC-MS/MS Method for Simultaneous Determination on a Dried Blood Spot of Multiple Analytes Relevant for Treatment Monitoring in Patients with Tyrosinemia Type IAnalytical Chemistry, 2011
- Dried Blood Spots as A Sampling Technique for The Quantitative Determination of Guanfacine in Clinical StudiesBioanalysis, 2011
- Glaxosmithkline’s Experience of Incurred Sample Reanalysis for Dried Blood Spot SamplesBioanalysis, 2011
- Rapid assay of rufinamide in dried blood spots by a new liquid chromatography–tandem mass spectrometric methodJournal of Pharmaceutical and Biomedical Analysis, 2011
- Use of Dried Plasma Spots in the Determination of Pharmacokinetics in Clinical Studies: Validation of a Quantitative Bioanalytical MethodAnalytical Chemistry, 2010
- Application of the DBS Methodology to a Toxicokinetic Study in Rats and Transferability of Analysis Between Bioanalytical LaboratoriesBioanalysis, 2010
- The Effect of Hematocrit on Assay Bias When Using DBS Samples for The Quantitative Bioanalysis of DrugsBioanalysis, 2010