Face and construct validity assessment of training models for intestinal anastomosis in low-birth-weight infants
Authors:
- 2 September 2021
- journal article
- research article
- Published by Springer Nature in Pediatric Surgery International
- Vol. 37 (12) , 1765-1772
Abstract
Purpose It is difficult to perform intestinal anastomosis in low-birth-weight infants because the intestinal diameter is small and the discrepancy in diameter of the proximal and distal intestines is often large, but there has been no optimal-sized training model. Therefore, we developed a new intestinal anastomosis training model that imitated the size of the intestine in low-birth-weight infants, and evaluated its face and construct validity. Methods Two intestinal models were developed with crossMedical, Inc. using a hydrophilic acrylic material (wet model) or a polyurethane soft resin (dry model). The inner diameter of the simulated intestinal tract was 15 mm on the oral end and 6 mm on the anal end. Thirteen pediatric surgeons performed anastomosis and responded to the questionnaire. Results In the questionnaire, the wet model had significantly higher scores than the dry model in “appearance”, “softness” and “usefulness for training”. In the anastomotic results of the wet model, the anastomosis leak pressure was significantly correlated with the number of intestinal anastomotic experiences in low-birth-weight infants (correlation coefficient = 0.64, P = 0.035). Conclusions The wet-type intestinal anastomosis model showed good face validity. Its leak pressure had a significant correlation with clinical experience; thus, construct validity was demonstrated.Keywords
This publication has 15 references indexed in Scilit:
- Pediatric Thoracoscopic Surgical Simulation Using a Rapid-Prototyped Chest Model and Motion Sensors Can Better Identify Skilled Surgeons Than a Conventional Box TrainerJournal of Laparoendoscopic & Advanced Surgical Techniques, 2016
- Evaluation of Three Sources of Validity Evidence for a Synthetic Thoracoscopic Esophageal Atresia/Tracheoesophageal Fistula Repair SimulatorJournal of Laparoendoscopic & Advanced Surgical Techniques, 2015
- Evaluation of Three Sources of Validity Evidence for a Laparoscopic Duodenal Atresia Repair SimulatorJournal of Laparoendoscopic & Advanced Surgical Techniques, 2015
- Objective assessment of the suture ligature method for the laparoscopic intestinal anastomosis model using a new computerized systemSurgical Endoscopy, 2014
- Validation of measures from a thoracoscopic esophageal atresia/tracheoesophageal fistula repair simulatorJournal of Pediatric Surgery, 2014
- Collaboration in simulation: The development and initial validation of a novel thoracoscopic neonatal simulatorJournal of Pediatric Surgery, 2013
- Is motion analysis a valid tool for assessing laparoscopic skill?Surgical Endoscopy, 2012
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Objective assessment of technical skills in surgeryBMJ, 2003
- Teaching and testing technical skillsThe American Journal of Surgery, 1993