Comparison of Coplanar and NonCoplanar VMAT Plans in HippocampusSparing Whole-Brain Radiotherapy
- 25 August 2026
- journal article
- Published by Erciyes Universitesi (DergiPark) in Sağlık Bilimleri Dergisi
- Vol. 35 (2) , 452-460
Abstract
This study aimed to evaluate the effects of coplanar and non-coplanar treatment plans generated using the volumetric modulated arc therapy technique on hippocampal sparing and doses delivered to other critical organs in whole-brain radiotherapy. Hippocampal-sparing whole-brain radiotherapy plans of eighteen patients diagnosed with brain metastases were retrospectively evaluated. All treatment plans were created and analyzed using the Monaco treatment planning system. The hippocampus was contoured in accordance with the Radiation Therapy Oncology Group guidelines, and plans were assessed in terms of target volume coverage, dose homogeneity, and doses to critical organs. No statistically significant difference was observed between coplanar and non-coplanar plans regarding target volume coverage and target volume–hippocampus dose parameters. However, non-coplanar plans demonstrated significantly better control of high-dose regions within the target volume. Hippocampal-sparing whole-brain radiotherapy represents an important approach that balances effective intracranial disease control with preservation of neurocognitive function. Both coplanar and non-coplanar techniques offer specific dosimetric advantages, and treatment planning should be individualized according to patient anatomy and clinical priorities.Keywords
This publication has 21 references indexed in Scilit:
- Hippocampal-sparing whole-brain radiotherapy under coplanar or noncoplanar VMATMedical Dosimetry, 2023
- RapidPlan hippocampal sparing whole brain model version 2—how far can we reduce the dose?Medical Dosimetry, 2022
- Hippocampal-sparing whole brain volumetric modulated arc therapy (VMAT) planning in Monaco: a “How-to” not pull your hair outMedical Dosimetry, 2021
- Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157Medical Physics, 2019
- Lens Dose-Response Prediction Modeling and Cataract Incidence in Patients With Retinoblastoma After Lens-Sparing or Whole-Eye Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2019
- Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at riskMedical Dosimetry, 2017
- An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT)Medical Dosimetry, 2015
- Hippocampus sparing in whole-brain radiotherapyStrahlentherapie und Onkologie, 2014
- Why avoid the hippocampus? A comprehensive reviewRadiotherapy and Oncology, 2010
- Hippocampal-Sparing Whole-Brain Radiotherapy: A “How-To” Technique Using Helical Tomotherapy and Linear Accelerator–Based Intensity-Modulated RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010