Surgical Technique: A Cup-in-Cup Technique to Restore Offset in Severe Protrusio Acetabular Defects
Authors:
- Thomas J. BlumenfeldTBThomas J. Blumenfeld
- William L. BargarWBWilliam L. Bargar
- 1 February 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (2) , 435-441
Abstract
E vertical and horizontal offset. Failure to restore offset can lead to impingement, leg length inequality, abductor weakness, and dislocation. Surgical Technique We developed a “cup-in-cup” technique in which a porous tantalum acetabular shell was impacted into supportive medial host bone. A second tantalum shell was then cemented in, and this shell’s diameter could be selected based on preoperative planning to achieve restoration of horizontal and vertical offset. Patients and Methods We implanted porous tantalum hemispheric shells in seven patients undergoing eight revision THAs. The average age was 73 years at the time of the procedure. Preoperative defects per the classification of Paprosky et al. were three IIC, four IIIA, and one IIIB. All patients were followed clinically and radiographically for a minimum of 12 months (average, 28 months; range, 12-50 months). Results Abductor strength was either improved by one grade (four hips) or unchanged (four hips). Horizontal offset was increased an average of 10.5 mm (range, 8-16 mm), and vertical offset improved by an average of 18.4 mm (range, 10-29 mm). There was no evidence of loosening or migration at the time of final followup. Conclusions At short-term followup, the early experience cautiously supports the use of this construct. Long-term followup and a larger patient experience will be required to determine the durability of this novel technique. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....Keywords
This publication has 17 references indexed in Scilit:
- Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum ComponentsThe Journal of Arthroplasty, 2010
- Management of Severe Bone Loss in Acetabular Revision Using a Trabecular Metal ShellThe Journal of Arthroplasty, 2008
- The Use of Tantalum Porous Metal Implants for Paprosky 3A and 3B DefectsThe Journal of Arthroplasty, 2007
- The Use of a Trabecular Metal Acetabular Component and Trabecular Metal Augment for Severe Acetabular DefectsThe Journal of Arthroplasty, 2006
- Fixation strength of an all-metal acetabular component cemented into an acetabular shell: A biomechanical analysisThe Journal of Arthroplasty, 2004
- COMPLEX REGIONAL PAIN SYNDROMEThe Journal of Bone and Joint Surgery. British volume, 2003
- Bridging Massive Acetabular Defects With the Triflange CupClinical Orthopaedics and Related Research, 2001
- The Burch-Schneider antiprotrusio cage in acetabular revision surgeryThe Journal of Arthroplasty, 2000
- Reconstruction of the deficient acetabulum with an oblong prosthesisThe Journal of Arthroplasty, 1998
- Acetabular defect classification and surgical reconstruction in revision arthroplastyThe Journal of Arthroplasty, 1994