Preliminary clinical experience with hyaluronan anti-adhesion gel in arthroscopic arthrolysis for posttraumatic elbow stiffness
Open Access
- 1 March 2013
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 14 (2) , 109-114
Abstract
Loss of motion of the elbow joint is a common finding after elbow trauma. It has been shown that arthroscopic treatment leads to excellent restoration of elbow motion, although it is still a demanding procedure. The aim of our cohort study was to assess clinical outcomes following treatment of posttraumatic elbow stiffness using arthroscopic arthrolysis with or without the associated use of a hyaluronan anti-adhesion gel. A cohort of 36 consecutive patients undergoing elbow arthroscopic arthrolysis were enrolled: 17 patients in the hyaluronan gel group and 19 in the control group. The patients underwent prospective control visits 30 and 75 days after surgery. Functional outcome was measured by the range of motion and the Liverpool elbow score (LES), whereas pain and quality of life were evaluated using the visual analogue scale and the SF-36 questionnaire, respectively. The range of motion and the overall LES score increased over time in both groups. The mean increase over time was statistically significant (p < 0.001) in both groups and there was no difference between the groups. There was also no interaction between time and treatment. The percentage of patients who reported pain decreased significantly over time (p = 0.0419) in the hyaluronan-treated group (suggesting limited contractions and better comfort during rehabilitation), but not in the control group. The intensity of pain decreased significantly over time in both groups (p < 0.0001) without any significant difference between the groups. All the changes in patient quality of life as measured by the SF-36 questionnaire were similar for the two groups of patients. No adverse event or complication related to the application of hyaluronan gel occurred. Our preliminary clinical experience showed promising results upon the use of hyaluronan gel, considering that it significantly reduced pain in the short term, facilitating a more comfortable rehabilitation. These findings should be confirmed by larger studies.Keywords
This publication has 24 references indexed in Scilit:
- Arthroscopic arthrolysis for posttraumatic elbow stiffnessJournal of Shoulder and Elbow Surgery, 2011
- Efficiency of Hyaloglide® in the prevention of the recurrence of adhesions after tenolysis of flexor tendons in zone II: a randomized, controlled, multicentre clinical trialJournal of Hand Surgery (European Volume), 2009
- Adhesion reduction after knee surgery in a rabbit model by Hyaloglide®, a hyaluronan derivative gelJournal of Orthopaedic Research, 2005
- Pharmacokinetic behaviour of ACP gel, an autocrosslinked hyaluronan derivative, after intraperitoneal administrationBiomaterials, 2005
- Reduction of Postoperative Perineural Adhesions by Hyaloglide Gel: An Experimental Study in the Rat Sciatic NerveOperative Neurosurgery, 2005
- Development and validation of an elbow scoreRheumatology, 2004
- Reduction of neural adhesions by biodegradable autocrosslinked hyaluronic acid gel after injury of peripheral nerves: an experimental studyJournal of Neurosurgery, 2004
- Biodegradation of hyaluronic acid derivatives by hyaluronidaseBiomaterials, 1994
- Arthroscopic Treatment of Posttraumatic Elbow Pain and StiffnessThe American Journal of Sports Medicine, 1994
- The Contents of Macromolecule Solutes in Flexor Tendon Sheath Fluid and Their Relation to Synovial FluidJournal of Hand Surgery (European Volume), 1992