Stability of radiomic features in CT perfusion maps
- 28 November 2016
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (24) , 8736-8749
Abstract
This study aimed to identify a set of stable radiomic parameters in CT perfusion (CTP) maps with respect to CTP calculation factors and image discretization, as an input for future prognostic models for local tumor response to chemo-radiotherapy. Pre-treatment CTP images of eleven patients with oropharyngeal carcinoma and eleven patients with non-small cell lung cancer (NSCLC) were analyzed. 315 radiomic parameters were studied per perfusion map (blood volume, blood flow and mean transit time). Radiomics robustness was investigated regarding the potentially standardizable (image discretization method, Hounsfield unit (HU) threshold, voxel size and temporal resolution) and non-standardizable (artery contouring and noise threshold) perfusion calculation factors using the intraclass correlation (ICC). To gain added value for our model radiomic parameters correlated with tumor volume, a well-known predictive factor for local tumor response to chemo-radiotherapy, were excluded from the analysis. The remaining stable radiomic parameters were grouped according to inter-parameter Spearman correlations and for each group the parameter with the highest ICC was included in the final set. The acceptance level was 0.9 and 0.7 for the ICC and correlation, respectively. The image discretization method using fixed number of bins or fixed intervals gave a similar number of stable radiomic parameters (around 40%). The potentially standardizable factors introduced more variability into radiomic parameters than the non-standardizable ones with 56–98% and 43–58% instability rates, respectively. The highest variability was observed for voxel size (instability rate >97% for both patient cohorts). Without standardization of CTP calculation factors none of the studied radiomic parameters were stable. After standardization with respect to non-standardizable factors ten radiomic parameters were stable for both patient cohorts after correction for inter-parameter correlations. Voxel size, image discretization, HU threshold and temporal resolution have to be standardized to build a reliable predictive model based on CTP radiomics analysis.Keywords
Funding Information
- Center for Clinical Research, University and University Hospital Zurich
- Clinical Research Priority Program Tumor Oxygenation of the University of Zurich
- Merck (Schweiz) AG
This publication has 47 references indexed in Scilit:
- Volumetric stratification of cT4 stage head and neck cancerStrahlentherapie und Onkologie, 2013
- Noise robust rotation invariant features for texture classificationPattern Recognition, 2013
- Fractal Dimension Estimation Methods for Biomedical Images2012
- Lung texture in serial thoracic CT scans: Assessment of change introduced by image registrationa)Medical Physics, 2012
- Reproducibility of Tumor Uptake Heterogeneity Characterization Through Textural Feature Analysis in 18F-FDG PETJournal of Nuclear Medicine, 2012
- Emerging Technologies for Improved Stratification of Cancer PatientsThe Cancer Journal, 2011
- Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation DetailsInternational Journal of Biomedical Imaging, 2011
- Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parametersActa Oncologica, 2010
- Identifying High Level Features of Texture PerceptionCVGIP: Graphical Models and Image Processing, 1993
- Textural features corresponding to textural propertiesIEEE Transactions on Systems, Man, and Cybernetics, 1989