Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced‐SSFP inversion recovery with interleaved sampling acquisition (CABIRIA)
Open Access
- 11 August 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 365-371
Abstract
Purpose: To develop a novel sequence for simultaneous quantification of T1 and T2 relaxation times in the myocardium based on the transient phase of the balanced steady‐state free precession.Methods: A new prototype sequence, named “cardiac balanced‐SSFP inversion recovery with interleaved sampling acquisition” (CABIRIA) was developed based on a single‐shot bSSFP readout following an inversion pulse. With this method, T1 and T2 values can be calculated from the analysis of signal evolution. The scan duration for a single slice in vivo was 8 heartbeats, thus feasible in a breath‐hold. The sequence was validated both in vitro by comparing it to conventional inversion recovery and multi‐echo spin‐echo methods and in 5 healthy volunteers by comparing it to the Modified Look‐Locker Inversion Recovery (MOLLI) sequence and to a T2 quantification sequence based on multi‐T2‐prepared bSSFP.Results: The method showed good agreement with conventional methods for both T1 and T2 measurements (concordance correlation coefficient ≥ 0.99) in vitro. In healthy volunteers the measured T1 values were 1227 ± 68 ms and T2 values 37.9 ± 2.4 ms, with similar inter‐ and intrasubject variability with respect to existing methods.Conclusion: The proposed CABIRIA method enables simultaneous quantification of myocardial T1 and T2 values with good accuracy and precision. Magn Reson Med 74:365–371, 2015.Keywords
This publication has 29 references indexed in Scilit:
- On myocardial siderosis and left ventricular dysfunction in hemochromatosisJournal of Cardiovascular Magnetic Resonance, 2013
- Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMRJournal of Cardiovascular Magnetic Resonance, 2012
- The protein binding substance Ibuprofen does not affect the T1 time or partition coefficient in contrast-enhanced cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- T1 mapping of the myocardium: Intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial regionJournal of Cardiovascular Magnetic Resonance, 2012
- Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2012
- Improved Detection of Myocardial Involvement in Acute Inflammatory Cardiomyopathies Using T2 MappingCirculation: Cardiovascular Imaging, 2012
- Myocardial T measurements in iron‐overloaded thalassemia: An in vivo study to investigate optimal methods of quantificationMagnetic Resonance in Medicine, 2008
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986