MRI of the Pelvis in Women: 3D Versus 2D T2-Weighted Technique
Authors:
- 1 July 2010
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (1) , 254-259
Abstract
OBJECTIVE. The purpose of this study was to compare triplanar 2D T2-weighted turbo spin-echo MR images with reformatted images from a 3D T2-weighted turbo spin-echo sequence in analogous planes with respect to acquisition time, image quality, artifacts, and lesion detection.MATERIALS AND METHODS. Forty-four consecutively enrolled women referred for pelvic MRI participated in the study. The protocol included 2D T2-weighted turbo spin-echo sequences in the axial, coronal, and sagittal planes and a single sagittal 3D T2-weighted turbo spin-echo sequence. The acquisition times of the 2D and 3D sequences were calculated. The sagittal 3D data sets were reformatted at 2-mm slice thickness in each plane and compared with the 2D data sets with respect to image quality, artifacts, and lesion detection.RESULTS. The mean acquisition time for the 3D sequence (419 seconds) was significantly shorter than acquisition time for the 2D sequences in three planes (728 seconds) (p < 0.0001). The readers favored the 3D reformat...Keywords
This publication has 9 references indexed in Scilit:
- Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequencesEuropean Radiology, 2008
- MRI of the female pelvis at 3T compared to 1.5T: Evaluation on high‐resolution T2‐weighted and HASTE imagesJournal of Magnetic Resonance Imaging, 2007
- Magnetic Resonance Imaging of the Body Trunk Using a Single-Slab, 3-Dimensional, T2-weighted Turbo-Spin-Echo Sequence With High Sampling Efficiency (SPACE) for High Spatial Resolution ImagingInvestigative Radiology, 2005
- Comparison of conventional fast spin echo, single‐shot two‐dimensional and three‐dimensional half‐fourier RARE for T2‐weighted female pelvic imagingJournal of Magnetic Resonance Imaging, 2004
- MR Imaging of Cervical Carcinoma: A Practical Staging ApproachRadioGraphics, 2000
- MRI of the female pelvisSeminars in Ultrasound, CT and MRI, 1999
- Comparison of ultrafast half‐Fourier single‐shot turbo spin‐echo sequence with turbo spin‐echo sequences for T2‐weighted imaging of the female pelvisJournal of Magnetic Resonance Imaging, 1998
- Magnetic resonance imaging of the female pelvisSeminars in Ultrasound, CT and MRI, 1998
- Magnetic resonance evaluation of congenital uterine anomaliesSeminars in Ultrasound, CT and MRI, 1994