nMARQ Ablation for Atrial Fibrillation: Results from a Multicenter Study
- 16 June 2015
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (7) , 724-729
Abstract
NMARQ AF Ablation: Background: nMARQ is a multipolar catheter designed to simultaneously ablate at multiple sites around the pulmonary vein (PV) circumference with a single radiofrequency application. We sought to define the safety and efficacy of atrial fibrillation (AF) ablation with the nMARQ catheter.Methods: In a multicenter study, patients with drug‐refractory AF were included. Procedural outcomes were documented at 1 year.Results: 374 patients underwent PV isolation using nMARQ (age 60 ± 10 years, 264 male), of whom 263 patients had paroxysmal AF (PAF), while 111 patients had persistent AF. A total of 1,468 of 1,474 veins (99.6%) were isolated with the nMARQ catheter alone. Thirty‐five (13%) PAF patients and 30 (27%) persistent AF patients underwent additional ablation at non‐PV sites (2.4 ± 1.4 non‐PV sites). Procedure time for PV isolation only was 1.9 ± 0.7 hours (fluoroscopy 24 ± 14 minutes). Procedure time for PV isolation and non‐PV ablation was 2.4 ± 1.0 hours (fluoroscopy 30 ± 23 minutes). Major adverse events occurred in two patients (0.5%); one esophago‐pericardial fistula and a second, mortality due to sepsis of unknown cause. One‐year follow‐up data were available in 65 (25%) PAF and 20 (18%) persistent AF patients. Forty‐two (65%) PAF and 13 (65%) persistent AF patients were free of arrhythmia at 1 year. In patients undergoing repeat procedures (n = 17) the most frequent points of PV reconnection were: anterior RSPV, inferior RIPV, and superior LSPV.Conclusions: AF ablation with nMARQ is associated with short procedure times and high acute success rates. Further research is necessary to more clearly define long‐term outcome.Keywords
Funding Information
- European Union Seventh Framework Programme (HEALTH-F2-2010-261057)
This publication has 12 references indexed in Scilit:
- Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacyEP Europace, 2014
- Incidences of esophageal injury during esophageal temperature monitoring: a comparative study of a multi-thermocouple temperature probe and a deflectable temperature probe in atrial fibrillation ablationJournal of Interventional Cardiac Electrophysiology, 2014
- Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolationHeart Rhythm, 2013
- Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2013
- Esophago‐pericardial Fistula Complicating Atrial Fibrillation Ablation Using a Novel Irrigated Radiofrequency Multipolar Ablation CatheterJournal of Cardiovascular Electrophysiology, 2013
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJACC, 2013
- Long‐term Outcomes of Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐analysisJournal of the American Heart Association, 2013
- Efficacy and safety of atrial fibrillation ablation with phased radiofrequency energy and multielectrode cathetersHeart Rhythm, 2012
- Prevalence and Causes of Fatal Outcome in Catheter Ablation of Atrial FibrillationJACC, 2009
- Esophageal Injury and Temperature Monitoring During Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2008