Simultaneous assessment of both lung morphometry and gas exchange function within a single breath‐hold by hyperpolarized 129Xe MRI
Authors:
- 16 May 2017
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (8)
Abstract
During the measurement of hyperpolarized 129Xe magnetic resonance imaging (MRI), the diffusion‐weighted imaging (DWI) technique provides valuable information for the assessment of lung morphometry at the alveolar level, whereas the chemical shift saturation recovery (CSSR) technique can evaluate the gas exchange function of the lungs. To date, the two techniques have only been performed during separate breaths. However, the request for multiple breaths increases the cost and scanning time, limiting clinical application. Moreover, acquisition during separate breath‐holds will increase the measurement error, because of the inconsistent physiological status of the lungs. Here, we present a new method, referred to as diffusion‐weighted chemical shift saturation recovery (DWCSSR), in order to perform both DWI and CSSR within a single breath‐hold. Compared with sequential single‐breath schemes (namely the ‘CSSR + DWI’ scheme and the ‘DWI + CSSR’ scheme), the DWCSSR scheme is able to significantly shorten the breath‐hold time, as well as to obtain high signal‐to‐noise ratio (SNR) signals in both DWI and CSSR data. This scheme enables comprehensive information on lung morphometry and function to be obtained within a single breath‐hold. In vivo experimental results demonstrate that DWCSSR has great potential for the evaluation and diagnosis of pulmonary diseases.Keywords
Funding Information
- National Natural Science Foundation of China (81227902 and 81625011)
This publication has 42 references indexed in Scilit:
- Hyperpolarized 129Xe MRI of the human lungJournal of Magnetic Resonance Imaging, 2013
- Single‐breath xenon polarization transfer contrast (SB‐XTC): Implementation and initial results in healthy humansJournal of Magnetic Resonance Imaging, 2012
- MOXE: A model of gas exchange for hyperpolarized 129Xe magnetic resonance of the lungMagnetic Resonance in Medicine, 2012
- Lung morphometry with hyperpolarized 129Xe: Theoretical backgroundMagnetic Resonance in Medicine, 2011
- Imaging lung microstructure in mice with hyperpolarized 3 He diffusion MRIMagnetic Resonance in Medicine, 2010
- Diffusion‐weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary diseaseMagnetic Resonance in Medicine, 2010
- Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129Proceedings of the National Academy of Sciences, 2010
- Imaging alveolar–capillary gas transfer using hyperpolarized 129 Xe MRIProceedings of the National Academy of Sciences, 2006
- Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysemaMagnetic Resonance in Medicine, 2006
- Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findingsJournal of Magnetic Resonance Imaging, 2001