Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation
Authors:
Open Access
- 24 February 2006
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 9 (2) , 022802
Abstract
We report the use of coherent Smith-Purcell radiation to measure the bunch length of femtosecond-scale, 15 MeV electron bunches produced by a 17 GHz rf accelerator. The Smith-Purcell radiation was produced by passing a train of electron bunches above a metal grating. The radiation was verified as Smith-Purcell radiation by measuring the resonance condition, dependence on beam current, and dependence on beam height above the grating. Measurements of the intensity of the radiation vs emission angle were analyzed to obtain the bunch length. The accelerator was operated in two different modes, producing bunches that were determined to have bunch lengths of 600 and . These nondestructive bunch length measurements were found to agree well with an independent, but destructive, measurement using a microwave deflecting cavity.
Keywords
This publication has 23 references indexed in Scilit:
- Electro-Optic Technique with Improved Time Resolution for Real-Time, Nondestructive, Single-Shot Measurements of Femtosecond Electron Bunch ProfilesPhysical Review Letters, 2004
- Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak cameraNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- First measurements of subpicosecond electron beam structure by autocorrelation of coherent diffraction radiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Measurement of femtosecond electron bunches using a rf zero-phasing methodPhysical Review E, 1998
- Coherent Smith-Purcell radiation as a diagnostic for subpicosecond electron bunch lengthNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- A noninvasive bunch length monitor for femtosecond electron bunchesApplied Physics Letters, 1997
- Coherent Smith-Purcell radiation as a pulse length diagnosticNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Observation of coherent diffraction radiation from bunched electrons passing through a circular aperture in the millimeter- and submillimeter-wavelength regionsPhysical Review E, 1995
- Spectrum of coherent synchrotron radiation in the far-infrared regionPhysical Review A, 1991
- Visible Light from Localized Surface Charges Moving across a GratingPhysical Review B, 1953