Revision Total Elbow Arthroplasty with the Semiconstrained Coonrad/Morrey Prosthesis
- 18 February 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (7) , 618-628
Abstract
Background: Revision total elbow arthroplasty (TEA) has increased, especially in young patients with high functional expectations. The objective of this study was to evaluate the long-term results of revision TEA with a single semiconstrained prosthesis. Methods: Thirty-four revision TEAs were performed with a Coonrad/Morrey prosthesis in 32 patients; 2 patients had bilateral procedures. The mean patient age was 61 years (range, 22 to 76 years), and the revision TEA was performed at a mean time of 7.8 years (range, 1.6 to 21 years) after the primary TEA. Etiologies for revisions were humeral and ulnar aseptic loosening (n = 14), ulnar aseptic loosening (n = 8), humeral aseptic loosening (n = 6), septic arthritis (n = 4), and unstable unlinked prostheses (n = 2). Clinical and radiographic evaluations were performed with systematic preoperative infection workup and quantification of bone loss. The mean follow-up was 11.4 years (range, 2 to 21 years). Results: The Mayo Elbow Performance Score (MEPS) at the last follow-up was excellent in 6 cases, good in 18 cases, fair in 8 cases, and poor in 2 cases, with a mean improvement (and standard deviation) between the preoperative values at 42.4 ± 16.1 points and the postoperative values at 81.8 ± 12 points (p < 0.001). The mean pain scores improved significantly from 6.7 ± 1.3 points preoperatively to 1.4 ± 1.4 points postoperatively (p < 0.001). The flexion-extension arc increased significantly (p = 0.02) from 74° ± 27° preoperatively to 100° ± 31° postoperatively. The total number of complications was 29 in 19 revision TEAs (56%). Twenty of the 29 complications simply required monitoring without surgical intervention. Six repeat surgical procedures were required, and 3 implant revisions (9%) were performed. Conclusions: Revision TEA with a semiconstrained prosthesis can provide good clinical results that can be maintained during follow-up. The rate of complications is high. Proper evaluation of the risk-benefit ratio is essential for each revision TEA and should be discussed with the patient. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 37 references indexed in Scilit:
- Total elbow replacement: outcome of 1,146 arthroplasties from the Scottish Arthroplasty ProjectActa Orthopaedica, 2013
- Incidence and implications of early postoperative wound complications after total elbow arthroplastyJournal of Shoulder and Elbow Surgery, 2011
- Radial nerve palsy after humeral revision in total elbow arthroplastyJournal of Shoulder and Elbow Surgery, 2011
- Complications of total elbow replacement: A systematic reviewJournal of Shoulder and Elbow Surgery, 2011
- Total elbow arthroplasty in rheumatoid arthritisActa Orthopaedica, 2009
- Arthrodesis of the Elbow With Two Locking Compression PlatesTechniques in Shoulder & Elbow Surgery, 2007
- Revision of failed total elbow arthroplasty with use of a linked implantThe Journal of Bone and Joint Surgery. British volume, 2006
- Revision of Unstable Capitellocondylar (Unlinked) Total Elbow ReplacementJournal of Bone and Joint Surgery, 2005
- Polyethylene Wear After Total Elbow ArthroplastyJournal of Bone and Joint Surgery, 2005
- Extensive Posterior Exposure of the ElbowClinical Orthopaedics and Related Research, 1982