Turbulent heat transfer and pressure drop in pinned annular regions
Open Access
- 1 January 2000
- journal article
- Published by FapUNIFESP (SciELO) in Journal of the Brazilian Society of Mechanical Sciences
- Vol. 22 (1) , 119-132
Abstract
Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rateKeywords
This publication has 8 references indexed in Scilit:
- A comparative study of elliptical and circular sections in one- and two-row tubes and plate fin heat exchangersInternational Journal of Heat and Fluid Flow, 1997
- Double-Pipe and Multitube Heat Exchangers with Plain and Longitudinal Finned TubesHeat Transfer Engineering, 1997
- Turbulent heat transfer and pressure drop in an internally finned equilateral triangular ductExperimental Thermal and Fluid Science, 1996
- Describing the uncertainties in experimental resultsExperimental Thermal and Fluid Science, 1988
- Heat transfer in automobile radiators of the tubular typeInternational Communications in Heat and Mass Transfer, 1985
- Cooling Air in Turbulent Flow with Internally Finned TubesHeat Transfer Engineering, 1979
- Analysis of Turbulent Flow and Heat Transfer in Internally Finned Tubes and AnnuliJournal of Heat Transfer, 1979
- Local and Average Transfer Coefficients for One-Row Plate Fin and Tube Heat Exchanger ConfigurationsJournal of Heat Transfer, 1974