Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans
Authors:
- L FabriziLFL Fabrizi
- M SparkesMSM Sparkes
- L HoreshLHL Horesh
- J F Perez-Juste AbascalJAJ F Perez-Juste Abascal
- A McEwanA McEwan
- R H BayfordRBR H Bayford
- R ElwesRER Elwes
- C D BinnieCBC D Binnie
- D S HolderDHD S Holder
- 20 April 2006
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (5) , S163-S174
Abstract
Electrical impedance tomography (EIT) has the potential to produce images during epileptic seizures. This might improve the accuracy of the localization of epileptic foci in patients undergoing presurgical assessment for curative neurosurgery. It has already been shown that impedance increases by up to 22% during induced epileptic seizures in animal models, using cortical or implanted electrodes in controlled experiments. The purpose of this study was to determine if reproducible raw impedance changes and EIT images could be collected during epileptic seizures in patients who were undergoing observation with video-electroencephalography (EEG) telemetry as part of evaluation prior to neurosurgery to resect the region of brain causing the epilepsy. A secondary purpose was to develop an objective method for processing and evaluating data, as seizures arose at unpredictable times from a noisy baseline. Four-terminal impedance measurements from 258 combinations were collected continuously using 32 EEG scalp electrodes in 22 seizure episodes from 7 patients during their presurgical assessment together with the standard EEG recordings. A reliable method for defining the pre-seizure baseline and recording impedance data and EIT images was developed, in which EIT and EEG could be acquired simultaneously after filtering of EIT artefact from the EEG signal. Fluctuations of several per cent over minutes were observed in the baseline between seizures. During seizures, boundary voltage changes diverged with a standard deviation of 1-54% from the baseline. No reproducible changes with the expected time course of some tens of seconds and magnitude of about 0.1% could be reliably measured. This demonstrates that it is feasible to acquire EIT images in parallel with standard EEG during presurgical assessment but, unfortunately, expected EIT changes on the scalp of about 0.1% are swamped by much larger movement and systematic artefact. Nevertheless, EIT has the unique potential to provide invaluable neuroimaging data for this purpose and may still become possible with improvements in electrode design and instrumentation.Keywords
This publication has 18 references indexed in Scilit:
- Tissue Resistance Changes and the Profile of Synchronized Neuronal Activity During Ictal Events in the Low-Calcium Model of EpilepsyJournal of Neurophysiology, 2004
- Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element methodNeuroImage, 2003
- A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software projectMeasurement Science and Technology, 2002
- Neuroimaging of EpilepsySeminars in Neurology, 2002
- Invasive EEG Monitoring in Children: When, Where, and What?Journal Of Clinical Neurophysiology, 1999
- Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its SubtractionNeuroImage, 1998
- Imaging of cortical spreading depression by EIT: implications for localization of epileptic fociPhysiological Measurement, 1994
- Update on surgical treatment of the epilepsiesNeurology, 1993
- Numerical tools for analysis and solution of Fredholm integral equations of the first kindInverse Problems, 1992
- Impedance Changes during Epileptic SeizuresEpilepsia, 1966