Rapid Detection of Norovirus from Fresh Lettuce Using Immunomagnetic Separation and a Quantum Dots Assay
Authors:
- Joseph KwonJKJoseph Kwon
- Jong-Soon ChoiJCJong-Soon Choi
- Kyeong-Hwan LeeKLKyeong-Hwan Lee
- Sung YangSYSung Yang
- Sang-Mu KoSKSang-Mu Ko
- Jae-Keun ChungJCJae-Keun Chung
- Se-Young ChoSCSe-Young Cho
- Duwoon KimDKDuwoon Kim
- 1 April 2013
- journal article
- Published by Elsevier in Journal of Food Protection
- Vol. 76 (4) , 707-711
Abstract
Current molecular methods that include PCR have been used to detect norovirus in many food samples. However, the protocols require removing PCR inhibitors and incorporate time-consuming concentration steps to separate virus from analyte for rapid and sensitive detection of norovirus. We developed an immunomagnetic separation (IMS) and a quantum dots (QDs) assay to detect norovirus eluted from fresh lettuce with Tris buffer containing 1% beef extract (pH 9.5). IMS facilitated viral precipitation with a 10-min incubation, whereas virus concentration using polyethylene glycol (PEG) requires more than 3 h and an additional high-speed centrifugation step to precipitate virus before reverse transcription PCR (RT-PCR) analysis. The fluorescence intensity of QDs was detected qualitatively on norovirus dilutions of 10(-1) to 10(-3) in a stool suspension (100 RT-PCR units/ml). The results suggest that a fluorescence assay based on IMS and QDs is valid for detecting norovirus qualitatively according to fluorescent signal intensity within the same virus detection limit produced by IMS-RT-PCR and PEG-RT-PCR.Keywords
This publication has 33 references indexed in Scilit:
- Comparative Recovery of Foodborne Viruses from Fresh ProduceFoodborne Pathogens and Disease, 2008
- An Outbreak of Norovirus Caused by Consumption of Oysters from Geographically Dispersed Harvest Sites, British Columbia, Canada, 2004Foodborne Pathogens and Disease, 2007
- Real-time PCR method with statistical analysis to compare the potential of DNA isolation methods to remove PCR inhibitors from samples for diagnostic PCRMolecular and Cellular Probes, 2007
- Real-Time Nucleic Acid Sequence-Based Amplification Assay for Detection of Hepatitis A VirusApplied and Environmental Microbiology, 2005
- An outbreak of norovirus gastroenteritis associated with wedding cakesEpidemiology and Infection, 2005
- Alloyed Semiconductor Quantum Dots: Tuning the Optical Properties without Changing the Particle SizeJournal of the American Chemical Society, 2003
- Zirconium hydroxide effectively immobilizes and concentrates human enteric virusesLetters in Applied Microbiology, 2002
- Quantum-dot nanocrystals for ultrasensitive biological labeling and multicolor optical encodingJournal of Biomedical Optics, 2002
- Rapid concentration and detection of hepatitis A virus from lettuce and strawberriesJournal of Virological Methods, 2000
- A Foodborne Outbreak of Gastroenteritis Associated with Norwalk‐like Viruses: First Molecular Traceback to Deli Sandwiches Contaminated during PreparationThe Journal of Infectious Diseases, 2000