In Vivo Kinematics after a Cruciate-substituting TKA
Authors:
- 1 March 2010
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (3) , 807-814
Abstract
Patterns of motion in the native knee show substantial variability. Guided motion prosthetic designs offer stability but may limit natural variability. To assess these limits, we therefore determined the in vivo kinematic patterns for patients having a cruciate-substituting TKA of one design and determined the intersurgeon variability associated with a guided-motion prosthetic design. Three-dimensional femorotibial contact positions were evaluated for 86 TKAs in 80 subjects from three different surgeons using fluoroscopy during a weightbearing deep knee bend. The average posterior femoral rollback of the medial and lateral condyles for all TKAs from full extension to maximum flexion was −14.0 mm and −23.0 mm, respectively. The average axial tibiofemoral rotation from full extension to maximum flexion for all TKAs was 10.8°. The average weightbearing range of motion (ROM) was 109º (range, 60º–150º; standard deviation, 18.7º). Overall, the TKA showed axial rotation patterns similar to those of the normal knee, although less in magnitude. Surgeon-to-surgeon comparison revealed dissimilarities, showing the surgical technique and soft tissue handling influence kinematics in a guided-motion prosthetic design. Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 39 references indexed in Scilit:
- Changes in Knee Kinematics Reflect the Articular Geometry after ArthroplastyClinical Orthopaedics and Related Research, 2008
- In vivo contact stresses during activities of daily living after knee arthroplastyJournal of Orthopaedic Research, 2008
- Factors Affecting Flexion after Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- Physiologic Kinematics as a Concept for Better Flexion in TKAClinical Orthopaedics and Related Research, 2006
- Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRIJournal of Biomechanics, 2005
- A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy imagesIEEE Transactions on Medical Imaging, 2003
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Functional Analysis of Pre and Post-Knee Surgery: Total Knee Arthroplasty and ACL ReconstructionJournal of Biomechanical Engineering, 1993
- Interaction between intrinsic knee mechanics and the knee extensor mechanismJournal of Orthopaedic Research, 1987