Head-to-head comparison of the Lyon Schuss and fixed flexion radiographic techniques. Long-term reproducibility in normal knees and sensitivity to change in osteoarthritic knees
- 1 November 2008
- journal article
- research article
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 67 (11) , 1562-1566
Abstract
Objective: The Lyon Schuss (LS) and fixed flexion (FF) views of the knee are superior to a conventional standing anteroposterior view in evaluating joint space narrowing (JSN) in osteoarthritis (OA). Both position the knee identically but only the LS aligns the medial tibial plateau (MTP) with the x-ray beam fluoroscopically. The present study provides the first head-to-head comparison of the LS and FF views. Methods: At baseline and 12 months, 62 OA and 99 control knees were imaged twice on the same day with LS and FF views. Minimum joint space width (mJSW) was measured by computer and MTP alignment was assessed from the distance between anterior and posterior margins of the MTP (intermargin distance, IMD). Reproducibility of measurements of mJSW and sensitivity to change were evaluated. Results: In normal knees, JSW did not vary over 12 months with either view. In OA knees, 12-month mJSN was 0.22 (0.43) mm with the LS view and −0.01 (0.46) mm with the FF view (p = 0.0002 and p = 0.92, respectively). Mean IMD was only half as large in LS as in FF views (0.9 (0.5) mm vs 1.9 (1.2) mm, pConclusions: LS and FF radiographs offer similar reproducibility in JSW measurement. However, presumably due to its superiority in aligning the MTP, the LS view is much more sensitive to JSN in OA knees.Keywords
This publication has 13 references indexed in Scilit:
- Change in joint space width: Hyaline articular cartilage loss or alteration in meniscus?Arthritis & Rheumatism, 2006
- Assessment of the radioanatomic positioning of the osteoarthritic knee in serial radiographs: comparison of three acquisition techniquesOsteoarthritis and Cartilage, 2006
- Influence of the quality of tibial plateau alignment on the reproducibility of computer joint space measurement from Lyon schuss radiographic views of the knee in patients with knee osteoarthritisOsteoarthritis and Cartilage, 2004
- Comparison of fixed-flexion positioning with fluoroscopic semi-flexed positioning for quantifying radiographic joint-space width in the knee: test-retest reproducibilitySkeletal Radiology, 2003
- Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: Comparison of standing anteroposterior and Lyon Schuss viewsArthritis & Rheumatism, 2003
- Effect of alignment of the medial tibial plateau and X-ray beam on apparent progression of osteoarthritis in the standing anteroposterior knee radiographArthritis & Rheumatism, 2001
- Quantificative evaluation of joint space width in femorotibal osteoarthritis: comparison of three radiographic viewsOsteoarthritis and Cartilage, 1998
- Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.Annals of the Rheumatic Diseases, 1995
- Hypertrophic repair of articular cartilage in experimental osteoarthrosis.Annals of the Rheumatic Diseases, 1983
- Radiological Assessment of Osteo-ArthrosisAnnals of the Rheumatic Diseases, 1957