Abstract
Objective: We report the development of a new peritoneal dialysis catheter. The purpose of the current study was to evaluate tissue response to this catheter. Design: In our catheter design, the catheter's cuffs are made from sintered titanium fiber mesh instead of the common Dacron material. The catheters were implanted in goats. During the study period, the catheter exit sites were observed once every 2 weeks. After 14 weeks, the catheters and surrounding tissues were processed for histology and analyzed. Results: We observed that catheters with titanium cuffs performed significantly better, compared with a commercial catheter design. Histology showed that titanium fibers evoked a lesser inflammatory response compared with Dacron fibers. In addition, the capsule surrounding the titanium cuff was significantly thinner. Conclusions: Supported by the obtained results, we conclude that the use of Dacron velour for anchorage of percutaneous catheters has to be reconsidered. Titanium fiber mesh has a great potential for application in percutaneous catheters.Keywords
This publication has 21 references indexed in Scilit:
- Cell and soft tissue interactions with methyl- and hydroxyl-terminated alkane thiols on gold surfacesBiomaterials, 1997
- A One Stage Versus Two Stage Surgical TechniqueASAIO Journal, 1996
- Tissue reaction to Dacron® velour and titanium fibre mesh used for anchorage of percutaneous devicesBiomaterials, 1996
- Long-Term Clinical Experience with Continuous Ambulatory Peritoneal Dialysis: Access-Related ProblemsJournal of Investigative Surgery, 1996
- Biocompatibility of silver-coated polyurethane catheters and silvercoated Dacron® materialBiomaterials, 1994
- Semi-Quantitative and Qualitative Histologic Analysis Method for the Evaluation of Implant BiocompatibilityJournal of Investigative Surgery, 1994
- The Moncrief-Popovich CatheterASAIO Journal, 1993
- Cell adhesion and growth on polymer surfaces with hydroxyl groups prepared by water vapour plasma treatmentBiomaterials, 1991
- A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium‐coated percutaneous implantsJournal of Biomedical Materials Research, 1991
- A Simple Method for Preparing Thin (10 μm) Histological Sections of Undecalcified Plastic Embedded Bone with ImplantsStain Technology, 1988