Comparison of volume, four- and eight-channel head coils using standard and parallel imaging
- 23 April 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 15 (8) , 1555-1562
Abstract
Array coils can potentially offer increased signal-to-noise ratio (SNR) over standard coils adjacent to the array elements, while preserving the SNR at the center of the volume. The SNR advantage should theoretically increase with the number of array elements. Parallel acquisition techniques (PAT), on the other hand, can benefit acquisition times or spatial resolution at a cost to SNR as well as image quality. This study examines the question of whether SNR and image quality are still acceptable with two different array coils (four and eight channels) in conjunction with PAT when compared to standard imaging with a volume coil. All imaging was on a 1.5 T MR scanner. T2-weighted, FLAIR, diffusion-weighted, and time of flight (TOF) angiography images were performed with and without PAT in a phantom and in ten healthy volunteers. The phantom measurements demonstrated superior SNR for the eight-channel coil versus the four-channel and standard head coils. Using the eight-channel head coil for in vivo imaging, image quality with PAT (acceleration factor=2) was scored similar to images without PAT using the volume coil. The four-channel head coil suffered from inhomogeneity, lower SNR and poorer image quality when using PAT compared to standard imaging with the volume head coil. Both the in vivo and the phantom results indicate that the eight-channel head coil should be used for the highest quality brain images; this coil can be combined with PAT sequences for shorter acquisition time without a significant decrease in image quality relative to a volume coil without PAT.Keywords
This publication has 17 references indexed in Scilit:
- Field‐of‐view limitations in parallel imagingMagnetic Resonance in Medicine, 2004
- New partially parallel acquisition technique in cerebral imaging: preliminary findingsEuropean Radiology, 2004
- 3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administrationEuropean Radiology, 2004
- Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experienceEuropean Radiology, 2004
- Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithmEuropean Radiology, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography.Journal of Magnetic Resonance Imaging, 2002
- Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2002
- A comparison of two methods for measuring the signal to noise ratio on MR imagesPhysics in Medicine & Biology, 1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999