Mandibular Advancement Device Treatment Efficacy Is Associated with Polysomnographic Endotypes
Authors:
- 1 March 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 18 (3) , 511-518
Abstract
Rationale: Mandibular advancement device (MAD) treatment efficacy varies among patients with obstructive sleep apnea. Objectives: The current study aims to explain underlying individual differences in efficacy using obstructive sleep apnea endotypic traits calculated from baseline clinical polysomnography: collapsibility (airflow at normal ventilatory drive), loop gain (drive response to reduced airflow), arousal threshold (drive preceding arousal), compensation (increase in airflow as drive increases), and the ventilatory response to arousal (increase in drive explained by arousal). On the basis of previous research, we hypothesized that responders to MAD treatment have a lower loop gain and milder collapsibility. Methods: Thirty-six patients (median apnea–hypopnea index [AHI], 23.5 [interquartile range (IQR), 19.7–29.8] events/h) underwent baseline and 3-month follow-up full polysomnography, with MAD fixed at 75% of maximal protrusion. Traits were estimated using baseline polysomnography according to Sands and colleagues. Response was defined as an AHI reduction ≥ 50%. Results: MAD treatment significantly reduced AHI (49.7%baseline [23.9–63.6], median [IQR]). Responders exhibited lower loop gain (mean [95% confidence interval], 0.53 [0.48–0.58] vs. 0.65 [0.57–0.73]; P = 0.020) at baseline than nonresponders, a difference that persisted after adjustment for baseline AHI and body mass index. Elevated loop gain remained associated with nonresponse after adjustment for collapsibility (odds ratio, 3.03 [1.16–7.88] per 1–standard deviation (SD) increase in loop gain [SD, 0.15]; P = 0.023). Conclusions: MAD nonresponders exhibit greater ventilatory instability, expressed as higher loop gain. Assessment of the baseline degree of ventilatory instability using this approach may improve upfront MAD treatment patient selection. Clinical trial registered with www.clinicaltrials.gov (NCT 01532050)Keywords
This publication has 35 references indexed in Scilit:
- A simplified method for determining phenotypic traits in patients with obstructive sleep apneaJournal of Applied Physiology, 2013
- Sleep endoscopy with simulation bite for prediction of oral appliance treatment outcomeJournal of Sleep Research, 2012
- Treatment of obstructive sleep apnea using a custom-made titratable duobloc oral appliance: a prospective clinical studySleep and Breathing, 2012
- Current opinions and clinical practice in the titration of oral appliances in the treatment of sleep-disordered breathingSleep Medicine Reviews, 2012
- A method for measuring and modeling the physiological traits causing obstructive sleep apneaJournal of Applied Physiology, 2011
- The effect of mandibular advancement on upper airway structure in obstructive sleep apnoeaThorax, 2010
- Treatment outcomes of mandibular advancement devices in positional and nonpositional OSA patientsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2010
- Optimal positive airway pressure predicts oral appliance response to sleep apnoeaEuropean Respiratory Journal, 2009
- Nasopharyngoscopic evaluation of oral appliance therapy for obstructive sleep apnoeaEuropean Respiratory Journal, 2009
- Effect of Weight Loss on Upper Airway Collapsibility in Obstructive Sleep ApneaAmerican Review of Respiratory Disease, 1991